HD59153: PART : BROKEN LINK BETWEEN A CATPART AND A CATFCT FILE AT THE O PENING

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • PART : BROKEN LINK BETWEEN A CATPart AND A
    CATfct FILE AT THE OPENING
    .
    Scenario
    1. Open CATIA
    2. File/Open UPPER_CABINET.CATPart
    .
    Result : the Open action is done without trouble
    since SpdFunctionalStartups.CATfct is correctly in
    \intel_a\resources\graphic.
    .
    3. File/Close
    4. File/Open LOWER_CAB.CATPart
    .
    Result : The open is NOT done correctly (see in
    FunctionnalBody.1) and the following error
    message is displayed : "The startup catalog files in
    the following list could not be found or contain the
    wrong information for the active document.
    SpdFunctionalStartups.CATfct
    Verify your installation or ask the owner of this
    document to send them."
    .
    5. File/open UPPER_CABINET.CATPart
    Result : It is ok
    .
    

Local fix

Problem summary

  • PART : BROKEN LINK BETWEEN A CATPart AND A CATfct FILE AT THE O
    PENING
    PART : BROKEN LINK BETWEEN A CATPart AND A
    CATfct FILE AT THE OPENING
    .
    Scenario
    1. Open CATIA
    2. File/Open UPPER_CABINET.CATPart
    .
    Result : the Open action is done without trouble
    since SpdFunctionalStartups.CATfct is correctly in
    \intel_a\resources\graphic.
    .
    3. File/Close
    4. File/Open LOWER_CAB.CATPart
    .
    Result : The open is NOT done correctly (see in
    FunctionnalBody.1) and the following error
    message is displayed : "The startup catalog files in
    the following list could not be found or contain the
    wrong information for the active document.
    SpdFunctionalStartups.CATfct
    Verify your installation or ask the owner of this
    document to send them."
    .
    5. File/open UPPER_CABINET.CATPart
    Result : It is ok
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    .
    Incident Diagnosis
    The second part that is opened in session, either
    UPPER_CABINET.CATPart or LOWER_CAB.CATPart,
    cannot find the refered catalog
    SpdFunctionalStartups.CATfct.
    .
    Restriction Explanation
    The link to the CATfct is not exactly the same in
    both CATPart documents:
    UPPER_CABINET.CATPart refers to
    SPDFUNCTIONALSTARTUPS.CATfct, in capital
    letters, whereas LOWER_CAB.CATPart refers to
    SpdFunctionalStartups.CATfct, in small letters.
    The error occurs when loading the second CATPart
    in session, either UPPER_CABINET or LOWER_CAB,
    because the name of the pointed CATfct has been
    already put in cache memory, and is
    case-different. Actually, the file on disk has small
    letters. One may refer to a pointed document
    with a wrong case if the document is not a
    catalog. But concerning catalogs, the user is not
    allowed to change the case.
    .
    By-Pass
    UPPER_CABINET.CATPart should be rebuilt, with the
    right SpdFunctionalStartups.CATfct.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD59153

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    515

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-11-14

  • Closed date

    2007-02-02

  • Last modified date

    2007-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 February 2007