APAR status
Closed as program error.
Error description
Scenario : 1- Tools / Options / Equipement and Systems / Electrical Process Interfacing tab - Electrical iXF Data Repository - System Repository / set the name of the directory the xml file is located. 2- Tools / Options / Equipement and Systems / Electrical Mapping tab - Catalog/Electrical objects mapping and select ElectricalParts.catalog 3- File / Open CATProduct 4- Go to Electrical Wire Routing Workbench 5- Select 'Select External Systems' 6- Make xml file Current System 7- Go to Electrical Assembly Design workbench 8- Select Manage Link icon 9- Select the line with Splice and Splice1 10- Select Place 11- Select Internal Splices 12- Select In Line 13- Select Splice Result: Error window : Diagnosis : Internal Error Bad value returned Expected Behavior: Once the splice is selected in the catalog the user would be prompted to select a bundle segment to instantiate the internal splice in the geometric bundle. .
Local fix
Problem summary
Electrical Assembly Design - Internal Splices can not be created within a geometric bundle with Manage Links icon Scenario : 1- Tools / Options / Equipement and Systems / Electrical Process Interfacing tab - Electrical iXF Data Repository - System Repository / set the name of the directory the xml file is located. 2- Tools / Options / Equipement and Systems / Electrical Mapping tab - Catalog/Electrical objects mapping and select ElectricalParts.catalog 3- File / Open CATProduct 4- Go to Electrical Wire Routing Workbench 5- Select 'Select External Systems' 6- Make xml file Current System 7- Go to Electrical Assembly Design workbench 8- Select Manage Link icon 9- Select the line with Splice and Splice1 10- Select Place 11- Select Internal Splices 12- Select In Line 13- Select Splice Result: Error window : Diagnosis : Internal Error Bad value returned Expected Behavior: Once the splice is selected in the catalog the user would be prompted to select a bundle segment to instantiate the internal splice in the geometric bundle. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP03. Incident Diagnosis Internal Splices can not be created within a geometric bundle. The data created was not proper. Hence an error was popping up which was difficult to interpret : 'Internal Error Bad value returned'. Correction Explanation Hence a user friendly error message was added : Definition of Internal Splice is not the expected one. Answer and By-Pass This new error message 'Definition of Internal Splice is not the expected one' appears on V5R17 SP3 and V5R18ga. .
Temporary fix
Comments
APAR Information
APAR number
HD57770
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-10-09
Closed date
2006-11-02
Last modified date
2006-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 November 2006