IBM Support

HD57196: CUSTOMIZED TOOLBAR IS MISSING AFTER A SECOND START OF CATIA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CUSTOMIZED TOOLBAR IS MISSING AFTER A
    SECOND START OF CATIA
    .
    SCENARIO
    0. Open CATIA V5R16SP6
    1. Go to WB Prismatic Machining
    - Tools/Customize/Toolbars/New
    - Toolbar Name: Nc-Tools
    - Add the 4 commands : "Generate NC Code
    Interactively", "Expand tree to machining
    operations", "Compute Tool Path" and "Remove
    Tool Path"
    .... Nc-Tools toolbar appears in WB Prismatic
    Machining.....
    2. Go to WB Surface Machining
    - Tools/Customize/Toolbars/New
    - Toolbar Name: Click on WB Prismatic Machining
    and choose Toolbar NC-Tools
    - click OK and close
    .... Nc-Tools toolbar appears in WB Surface
    Machining.....
    3. Close CATIA
    .
    4. Re-open CATIA
    5. Go to Assembly design
    6. Go to WB Prismatic Machining
    .... No problem, Nc-Tools toolbar appears....
    7. Go to WB Surface Machining
    .... Nc-Tools toolbar appears.....
    8. Close CATIA
    .
    9. Re-open CATIA
    10. Go to WB Prismatic Machining or Surface
    Machining
    .... PROBLEM : the customized tools does not exist
    anymore.
    .
    

Local fix

Problem summary

  • CUSTOMIZED TOOLBAR IS MISSING AFTER A SECOND START OF CATIA
    CUSTOMIZED TOOLBAR IS MISSING AFTER A
    SECOND START OF CATIA
    .
    SCENARIO
    0. Open CATIA V5R16SP6
    1. Go to WB Prismatic Machining
    - Tools/Customize/Toolbars/New
    - Toolbar Name: Nc-Tools
    - Add the 4 commands : "Generate NC Code
    Interactively", "Expand tree to machining
    operations", "Compute Tool Path" and "Remove
    Tool Path"
    .... Nc-Tools toolbar appears in WB Prismatic
    Machining.....
    2. Go to WB Surface Machining
    - Tools/Customize/Toolbars/New
    - Toolbar Name: Click on WB Prismatic Machining
    and choose Toolbar NC-Tools
    - click OK and close
    .... Nc-Tools toolbar appears in WB Surface
    Machining.....
    3. Close CATIA
    .
    4. Re-open CATIA
    5. Go to Assembly design
    6. Go to WB Prismatic Machining
    .... No problem, Nc-Tools toolbar appears....
    7. Go to WB Surface Machining
    .... Nc-Tools toolbar appears.....
    8. Close CATIA
    .
    9. Re-open CATIA
    10. Go to WB Prismatic Machining or Surface
    Machining
    .... PROBLEM : the customized tools does not exist
    anymore.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R16SP08 AND ON V5R17SP03.
    .
    General behavior :
    If it is marked "customized", each customization
    setting (from Tools/Customize) is saved at the
    closure of a CATIA session.
    .
    Incident diagnosis :
    During the first session, the user customized some
    toolbar settings. Those settings were then
    marked "customized". Therefore, they were saved
    during the session closure. At the opening of the
    second session, those settings were well read and
    applied. But they were no longer correctly
    marked "customized". That is why they were lost
    (not saved) when exiting the second session (and
    then not visible on third and others sessions.)
    .
    Correction explanation :
    The customized workshop is now correctly marked
    as "customized" after reading the customization
    settings in the second Catia session, so that the
    customization is now saved when exiting the second
    session (and all the future sessions...)
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD57196

  • Reported component name

    CATIA V5 SOLARI

  • Reported component ID

    569104000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-09-20

  • Closed date

    2006-10-20

  • Last modified date

    2006-12-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 SOLARI

  • Fixed component ID

    569104000

Applicable component levels

  • R516 PSN SP51608

       UP06/11/27 I 1000

  • R517 PSN SP51703

       UP06/12/11 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 December 2006