OM: WARM START / CATIA ABENDS AFTER WARM START IS EXECUTED. . SETTINGS: 1) Start CATIA V5R16SP5. 2) Select the "Tools/Options" on menu bar. The "Options" panel is displayed. 3) Select the "Options" / "General" in the tree. 4) Click on "General" tab. 5) Activate "Incremental backup". The "Warning" panel is displayed, and Click "OK" button. 6) Click "OK" button on "Options" panel. 7) End CATIA. . SCENARIO: 8) Again, start CATIA. 9) Open the "H0270.CATPart" file. Workbench: GSD 10) Click the "Sketch" icon. 11) Click the "Plane.1" on tree. The "Workbench" is changed into "Sketcher". 12) Click the "Project 3D Elements" icon. 13) Use a "Section trap" and select a "Surface.1". "3D element (Surface.1) is projected. 14) Click the "Exit workbench" icon. ABEND occurs. 15) After "ABEND" occurs, start CATIA again. The "Warm-start" panel is displayed, Click "Yes" button. "Warm Start" process is started. ABEND occurs during "Warm Start" process. The model is not restored. This is a problem. . .
Local fix
Problem summary
OM: WARM START / CATIA ABENDS AFTER WARM START IS EXECUTED. OM: WARM START / CATIA ABENDS AFTER WARM START IS EXECUTED. . SETTINGS: 1) Start CATIA V5R16SP5. 2) Select the "Tools/Options" on menu bar. The "Options" panel is displayed. 3) Select the "Options" / "General" in the tree. 4) Click on "General" tab. 5) Activate "Incremental backup". The "Warning" panel is displayed, and Click "OK" button. 6) Click "OK" button on "Options" panel. 7) End CATIA. . SCENARIO: 8) Again, start CATIA. 9) Open the "H0270.CATPart" file. Workbench: GSD 10) Click the "Sketch" icon. 11) Click the "Plane.1" on tree. The "Workbench" is changed into "Sketcher". 12) Click the "Project 3D Elements" icon. 13) Use a "Section trap" and select a "Surface.1". "3D element (Surface.1) is projected. 14) Click the "Exit workbench" icon. ABEND occurs. 15) After "ABEND" occurs, start CATIA again. The "Warm-start" panel is displayed, Click "Yes" button. "Warm Start" process is started. ABEND occurs during "Warm Start" process. The model is not restored. This is a problem. . .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 16. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 18 GA level AND ON V5R17SP03. . Incident Diagnosis: An applicative crash causes warmstart data-recovering process to abend. . Reason: The applicative crash is solved now and not reproducible. Thus warmstart does not have to recover the data and do not crash. Even if we kill CATIA externally at that step, still data is recovered without abend. . .
APAR Information
APAR number
HD56115
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-08-22
Closed date
2006-11-09
Last modified date
2006-12-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN SP51703
UP06/12/11 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
11 December 2006