IBM Support

HD55213: PDG / THREAD STANDARD TO REMOVE IS NOT SEEN WHEN CATREFFILES HA S MORE THAN ONE PATH.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • PDG / THREAD STANDARD TO REMOVE IS NOT
    SEEN WHEN CATREFFILES HAS MORE THAN ONE
    PATH.
    .
    SCENARIO:
    1. Open the attached CATPart.
    2.Go into Thread definition.
    3. The standard file is used  "NIHS_06_02" for the
    thread.
    4. Click on remove button.
    5. You see the used standard file NIHS_06_02.
    6. Close Catia.
    7. Now open environment file from R16.
    8. Change the path or add a new path to this
    variable
    CATReffilesPath=...\B16\intel_a\reffiles.
    9. Restart Catia V5R16SP04.
    10. Open the CATPart.
    11.Go into Thread definition.
    12.Click on Remove button.
    .
    OBSERVATION:
    The standard file is no more present.
    .
    EXPECTED RESULT:
    The standard file should be present.
    .
    .
    

Local fix

Problem summary

  • PDG / THREAD STANDARD TO REMOVE IS NOT SEEN WHEN CATREFFILES HA
    S MORE THAN ONE PATH.
    PDG / THREAD STANDARD TO REMOVE IS NOT
    SEEN WHEN CATREFFILES HAS MORE THAN ONE
    PATH.
    .
    SCENARIO:
    1. Open the attached CATPart.
    2.Go into Thread definition.
    3. The standard file is used  "NIHS_06_02" for the
    thread.
    4. Click on remove button.
    5. You see the used standard file NIHS_06_02.
    6. Close Catia.
    7. Now open environment file from R16.
    8. Change the path or add a new path to this
    variable
    CATReffilesPath=...\B16\intel_a\reffiles.
    9. Restart Catia V5R16SP04.
    10. Open the CATPart.
    11.Go into Thread definition.
    12.Click on Remove button.
    .
    OBSERVATION:
    The standard file is no more present.
    .
    EXPECTED RESULT:
    The standard file should be present.
    .
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 16.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    CATIA VERSION 5 RELEASE 18 GA level AND ON
    V5R17SP01.
    .
    Incident Diagnosis
    PDG / THREAD STANDARD TO REMOVE IS NOT
    SEEN WHEN CATREFFILES HAS MORE THAN ONE
    PATH.
    .
    Additioanl Information:
    The problem was submitted and reproduced on
    V5R16 SP04.
    .
    

APAR Information

  • APAR number

    HD55213

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-07-20

  • Closed date

    2006-07-21

  • Last modified date

    2006-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R517 PSN SP51701

       UP06/10/02 I 1000