APAR status
Closed as program error.
Error description
GSD / TRANSLATE / BAD BEHAVIOR WHILE MOVING THE CURSOR OVER GEOMETRY DURING TRANSLATE COMMAND. . SCENARIO: 1.Clear all CATSettings and start CATIA. 2.Open Supplied CATProduct. 3.Expand instance node in specification tree. 4.Expand PartBody in specification tree. 5.Select MANIFOLD_SOLID_BREP #1017487 in specification tree. . OBSERVATION1: The selection in geometry area is good and correct. . 6.Zoom in the geometry and select one of the edge of blue face. . OSERVATION2: An arrow is displayed in the geometry area. . 7.Select MANIFOLD_SOLID_BREP #1017487 in specification tree. . OBSERVATION3: The selection in geometry area is bad. The display is like clippings. Though the delay in selection cannot be measured in time but can be found out very easily visually. . 8.Double click on PartBody and select GSD workbench. 9.Click on Translate icon. Translate dialog box appears. 10.Move the cursor over the MANIFOLD_SOLID_BREP #1017487 in geometry area. . OBSERVATION4: The selection in geometry area is bad. The display is like clippings. Though the delay in selection cannot be measured in time but can be found out very easily visually. . EXPECTED RESULT: The behavior observed in OBSERVATION3 and 4 should be same as in OBSERVATION1 of this scenario. .
Local fix
Problem summary
GSD / TRANSLATE / BAD BEHAVIOR WHILE MOVING THE CURSOR OVER GEOMETRY DURING TRANSLATE COMMAND. . SCENARIO: 1.Clear all CATSettings and start CATIA. 2.Open Supplied CATProduct. 3.Expand instance node in specification tree. 4.Expand PartBody in specification tree. 5.Select MANIFOLD_SOLID_BREP #1017487 in specification tree. . OBSERVATION1: The selection in geometry area is good and correct. . 6.Zoom in the geometry and select one of the edge of blue face. . OSERVATION2: An arrow is displayed in the geometry area. . 7.Select MANIFOLD_SOLID_BREP #1017487 in specification tree. . OBSERVATION3: The selection in geometry area is bad. The display is like clippings. Though the delay in selection cannot be measured in time but can be found out very easily visually. . 8.Double click on PartBody and select GSD workbench. 9.Click on Translate icon. Translate dialog box appears. 10.Move the cursor over the MANIFOLD_SOLID_BREP #1017487 in geometry area. . OBSERVATION4: The selection in geometry area is bad. The display is like clippings. Though the delay in selection cannot be measured in time but can be found out very easily visually. . EXPECTED RESULT: The behavior observed in OBSERVATION3 and 4 should be same as in OBSERVATION1 of this scenario.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP01 AND V5R16SP07. Additional Closure Information: . Incident Diagnosis: Bad performance when prehighlight an object. . Correction Explanation: Bad performance is due to the fact that a small arrow used as a visual feedback to ease edge selection is rendered multiple times whereas it is only necessary to render it once or not to render it at all if the surface to highlight doesn't need this visual feedback. Problem fixed. . Answer and By-Pass: none
Temporary fix
Comments
APAR Information
APAR number
HD54913
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-07-12
Closed date
2010-08-30
Last modified date
2010-08-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R516 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
30 August 2010