APAR status
Closed as suggestion for future release.
Error description
THE REFERANCE DIMENSION IS NOT CREATED WITH GENERATE DIMENSION FUNCTION . Scenario 1) Start CATIA V5R16SP02. 2) Open the file : "Prart1.CATPart". (Workbench : "PartDesign" ) 3) Check the Dimension of "Sketch.1" and "Sketch.2". >>"Sketch.1" has a Reference Dimension. >>"Sketch.2" has a Dimension. 4) Open the file:"Drawing1.CATDrawing". (Workbench : "Drafting" ) 5) Zoon In the Drawing sheet. 6) Click "Generate Dimensions" icon. >>"Generated Dimensions Analysis" dialog box is displayed. . < Result 1 > The number of Dimension is One. >>>This is the problem. 7) Click "OK" button. < Result 2 > "Reference Dimension" is not created. >>>This is the problem. . < Result to expect > "Reference Dimension" should be created with "Generate Dimensions" command. .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT WHICH CANNOT BE INCORPORATED IN VERSION V5R17 PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A REQUIREMENT FORM. . Incident Diagnosis THE REFERENCE DIMENSION IS NOT CREATED WITH GENERATE DIMENSION FUNCTION . Development Request Justification When generating dimensions, only dimensions associated to 3d element seen in the view are created. Sometimes we are not able to detect that 3d elements which are visualized in the view and that's why,by default, corresponding dimensions are not created. In this incident, we are not able to detect that the use-edges that are seen in the view. There is a need of an impacting and expensive development that cannot be done on R17 level. . Answer and By-Pass Use the Dimension Generation Filters dialog box. Check the option "...associated with unrepresented elements", dimensions will be generated. .
APAR Information
APAR number
HD53303
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-05-31
Closed date
2006-06-09
Last modified date
2006-06-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
09 June 2006