IBM Support

HD50654: MMG / UNABLE TO COMPUTE TOOLPATH IN R16

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MMG / UNABLE TO COMPUTE TOOLPATH IN R16
    SCENARIO :
    1. The Part and Process used for this was created
    and locked in R14. This works as expected in R14.
    2. Start up R16 SP2.
    3. Open up the Process1.CATProcess and replay
    the locked Multi-Axis Curve Machining.1 MO.  The
    cutter moves as expected avoiding the check
    surface.
    4. Unlock Multi-Axis Curve Machining.1 MO and
    then open it up for editing.
    5. Switch to the Machining folder and switch the
    Tool path style from Zig zag to One way and then
    switch right back to Zig zag.
    6. Replay again. You will see that it no longer
    computes the cutter paths and instead displays the
    warning shown. There is no way to make this work
    in R16 SP2.
    This problem makes the Multi-Axis Curve
    machining function unusable if checks are required.
    Additional Info :
    Just unlock MO ,force-compute toolpath,It fails with
    same result
    .
    

Local fix

Problem summary

  • MMG / UNABLE TO COMPUTE TOOLPATH IN R16
    MMG / UNABLE TO COMPUTE TOOLPATH IN R16
    SCENARIO :
    1. The Part and Process used for this was created
    and locked in R14. This works as expected in R14.
    2. Start up R16 SP2.
    3. Open up the Process1.CATProcess and replay
    the locked Multi-Axis Curve Machining.1 MO.  The
    cutter moves as expected avoiding the check
    surface.
    4. Unlock Multi-Axis Curve Machining.1 MO and
    then open it up for editing.
    5. Switch to the Machining folder and switch the
    Tool path style from Zig zag to One way and then
    switch right back to Zig zag.
    6. Replay again. You will see that it no longer
    computes the cutter paths and instead displays the
    warning shown. There is no way to make this work
    in R16 SP2.
    This problem makes the Multi-Axis Curve
    machining function unusable if checks are required.
    Additional Info :
    Just unlock MO ,force-compute toolpath,It fails with
    same result
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 17 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R16SP04.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD50654

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-03-13

  • Closed date

    2006-03-31

  • Last modified date

    2006-04-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R516 PSN SP51604

       UP06/04/11 I 1000