IBM Support

HD48700: ITEV5CV5 : CAN'T OPEN CATIA IN VISUALIZATION MODE AFTER APPLYIN G THE ATTRIBUTEMAPPING XML FILE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Make the BOM structure and its CV5 data.
    2. Select "0010.01 | PK3" and send to "CATIA V5
    As Assembly"
    3. Select the menu "Tools-Options..." and then set
    options for the attribute mapping .
    [Scenario - Normal Case]
    4. Close the CATIA and then re-launch CATIA with
    the same assembly
    5. Open properties of the assembly 'PK3
    [Scenario - Bad Case]
    6. Select the menu "Tools-Options..." and then set
    visualization mode.
    7. Close the CATIA and then re-launch CATIA with
    the same assembly.
    .
    ACTUAL RESULT:
    CATIA can't be launched with Command
    interrupted error.
    .
    EXPECTED RESULT:
    CATIA should launch in visulalisation mode without
    any error.
    .
    REGRESSION LEVEL:
    This problem did not happen in R14 SP3.
    .
    .
    

Local fix

Problem summary

  • ITEV5CV5 : CAN'T OPEN CATIA IN VISUALIZATION MODE AFTER APPLYIN
    G THE ATTRIBUTEMAPPING XML FILE.
    Scenario:
    1. Make the BOM structure and its CV5 data.
    2. Select "0010.01 | PK3" and send to "CATIA V5
    As Assembly"
    3. Select the menu "Tools-Options..." and then set
    options for the attribute mapping .
     Scenario - Normal Case
    4. Close the CATIA and then re-launch CATIA with
    the same assembly
    5. Open properties of the assembly 'PK3
     Scenario - Bad Case
    6. Select the menu "Tools-Options..." and then set
    visualization mode.
    7. Close the CATIA and then re-launch CATIA with
    the same assembly.
    .
    ACTUAL RESULT:
    CATIA can't be launched with Command
    interrupted error.
    .
    EXPECTED RESULT:
    CATIA should launch in visulalisation mode without
    any error.
    .
    REGRESSION LEVEL:
    This problem did not happen in R14 SP3.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON ENOVIA
    VERSION 5 RELEASE 17 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R16SP03,V5R15SP07 and V5R14SP09.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD48700

  • Reported component name

    ENOVIA LCA NT>X

  • Reported component ID

    569151700

  • Reported release

    514

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-01-18

  • Closed date

    2006-02-03

  • Last modified date

    2009-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA LCA NT>X

  • Fixed component ID

    569151700

Applicable component levels

  • R514 PSN SP51409

       UP06/04/06 N 1000

  • R515 PSN SP51507

       UP06/03/27 I 1000

  • R516 PSN SP51603

       UP06/03/06 I 1000