Error description
PARTDESIGN / NO PROPERTIES ARE AVAILABLE FOR BOOLEANED OBJECTS EVEN IF BOTH THE BODIES ARE NON-HYBRID SCENARIO: . 1. Load the attached CATPart in Non-Hybrid Mode Note that both the Bodies involved are Non-Hybrid 2. Ensure that the Part Body is defined in Work object 3. Click MB3 on Body.2 and select Body.2 Objects/ Add 4. Add Body to part Body . OBSERVATION 1: Boolean Add is created but Body.2 remains in the initial position and a replica is created under Add in the SPEcTREE. . 5. Select a Face originally belonging to Pad.2 and Select Properties in the contextual menu. . OBSERVATION 2: A warning Occurs: No properties available for these objects. . EXPECTED RESULT: The Warning should not occur and the USER must be able to Edit the Properties as both the bodies involved in Boolean operation are Non-Hybrid. . .
Local fix
Problem summary
PARTDESIGN / NO PROPERTIES ARE AVAILABLE FOR BOOLEANED OBJECTS EVEN IF BOTH THE BODIES ARE NON-HYBRID PARTDESIGN / NO PROPERTIES ARE AVAILABLE FOR BOOLEANED OBJECTS EVEN IF BOTH THE BODIES ARE NON-HYBRID SCENARIO: . 1. Load the attached CATPart in Non-Hybrid Mode Note that both the Bodies involved are Non-Hybrid 2. Ensure that the Part Body is defined in Work object 3. Click MB3 on Body.2 and select Body.2 Objects/ Add 4. Add Body to part Body . OBSERVATION 1: Boolean Add is created but Body.2 remains in the initial position and a replica is created under Add in the SPEcTREE. . 5. Select a Face originally belonging to Pad.2 and Select Properties in the contextual menu. . OBSERVATION 2: A warning Occurs: No properties available for these objects. . EXPECTED RESULT: The Warning should not occur and the USER must be able to Edit the Properties as both the bodies involved in Boolean operation are Non-Hybrid. . .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 15. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 17 GA level . ADDITIONAL INFORMATION: Note that the problem is also not reproduced on R16 SP 03. On these levels, the property can be edited. .
APAR Information
APAR number
HD48204
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
515
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-01-05
Closed date
2006-01-06
Last modified date
2006-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 January 2006