IBM Support

HD48162: SPECIFICATION AUTHORIZATION GETS RESET WHEN NEW SPECIFICATION I S ADDED AND CONNECTED TO PC .

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SPECIFICATION AUTHORIZATION GETS RESET
    WHEN NEW SPECIFICATION IS ADDED AND
    CONNECTED TO PC .
    Problem Description-
    Step by step scenario:
    1. Create PC and PRC Hierarchy
    PC1
    PRC1
    PRC2
    PC2
    PRC3
    PRC4
    2. Configure all PRCs
    3. Create Category CAT1 and Specification SPEC1
    below CAT1
    4. Attach Object PC1 to CAT1
    5. Create Specification SPEC2 below CAT1
    6. On SPEC2 , attach object PRC2.
    7. Check "View Attached Objects" dialog you can
    see SPEC1 is authorizedto PC1 and all it's children
    and SPEC2 is only to PRC2 as desired.
    8. Now Create SPEC3 below CAT1 , and on SPEC3
    Attach Object PC1.
    9. Again Check "View Attached Object" dialog , this
    time previous authorization for SPEC2 is not reset
    and SPEC2 is now Authorized to all PC and PRC
    below PC1.
    Expected Result - SPEC2 should maintain it's
    specific Authorizations, when Userwants to attach
    objects to another specific Specifications.
    .
    

Local fix

Problem summary

  • SPECIFICATION AUTHORIZATION GETS RESET WHEN NEW SPECIFICATION I
    S ADDED AND CONNECTED TO PC .
    SPECIFICATION AUTHORIZATION GETS RESET
    WHEN NEW SPECIFICATION IS ADDED AND
    CONNECTED TO PC .
    Problem Description-
    Step by step scenario:
    1. Create PC and PRC Hierarchy
    PC1
    PRC1
    PRC2
    PC2
    PRC3
    PRC4
    2. Configure all PRCs
    3. Create Category CAT1 and Specification SPEC1
    below CAT1
    4. Attach Object PC1 to CAT1
    5. Create Specification SPEC2 below CAT1
    6. On SPEC2 , attach object PRC2.
    7. Check "View Attached Objects" dialog you can
    see SPEC1 is authorizedto PC1 and all it's children
    and SPEC2 is only to PRC2 as desired.
    8. Now Create SPEC3 below CAT1 , and on SPEC3
    Attach Object PC1.
    9. Again Check "View Attached Object" dialog , this
    time previous authorization for SPEC2 is not reset
    and SPEC2 is now Authorized to all PC and PRC
    below PC1.
    Expected Result - SPEC2 should maintain it's
    specific Authorizations, when Userwants to attach
    objects to another specific Specifications.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON ENOVIA
    VERSION 5 RELEASE 17 GA level.
    Note -  If we attach a PRC to specification which is
    already attach to the parent category, then we
    need to stop this attaching and propagation of
    PRC ,Otherwise it will attach to all the specs in the
    Tree and thus will do reseting of authorizations.
    Now in R17 GA if you attach the already category
    attached PRC to the specification ,then a note will
    appear at the bottom stating that 'category already
    attached to object.Use the VIEW ATTACHED
    OBJECTS to set the specification attachments.'
    Also the R17 documentation will be modified so as
    to deliver the right information about setting the
    specification attachment.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD48162

  • Reported component name

    ENOVIA LCA NT>X

  • Reported component ID

    569151700

  • Reported release

    514

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-01-05

  • Closed date

    2006-02-17

  • Last modified date

    2006-02-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA LCA NT>X

  • Fixed component ID

    569151700

Applicable component levels

  • R517 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDJRN","label":"ENOVIA LCA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
17 February 2006