  • PMG : Retract Macro paths change direction.
    .
    SCENARIO:
    1- Launch CATIA V5R15SP01
    2- Open the provided Simple.CATProcess
    3- Double click on View 5
    4- In the first Tool Change, Remove Toolpath on
    the MO
    5- Replay the toolpath choosing color mode
    RESULT:
    Retract is following tool axis
    6- Close CATIA without saving
    7- Launch CATIA V5R16GA
    8- Open the provided Simple.CATProcess
    9- Double click on View 5
    10- In the first Tool Change, Remove Toolpath on
    the MO
    11- Replay the toolpath choosing color mode
    PROBLEM:
    Retract is not correct, it is perpendicular to the tool
    axis
    ADDING INFORMATIONS :
    This problem occurs for all MO in all Tool changes
    in this CATProcess
    .
    

Local fix

Problem summary

  • PMG : Retract Macro paths change direction
    PMG : Retract Macro paths change direction.
    .
    SCENARIO:
    1- Launch CATIA V5R15SP01
    2- Open the provided Simple.CATProcess
    3- Double click on View 5
    4- In the first Tool Change, Remove Toolpath on
    the MO
    5- Replay the toolpath choosing color mode
    RESULT:
    Retract is following tool axis
    6- Close CATIA without saving
    7- Launch CATIA V5R16GA
    8- Open the provided Simple.CATProcess
    9- Double click on View 5
    10- In the first Tool Change, Remove Toolpath on
    the MO
    11- Replay the toolpath choosing color mode
    PROBLEM:
    Retract is not correct, it is perpendicular to the tool
    axis
    ADDING INFORMATIONS :
    This problem occurs for all MO in all Tool changes
    in this CATProcess
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 16.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    CATIA VERSION 5 RELEASE 17 GA level AND ON
    V5R16SP03.
    THIS PROBLEM IS ALSO NOT REPRODUCIBLE ON
    V5R16 SP02.
    .
    Incident Diagnosis
    Retract Macro paths change direction
    .
    Reason
    unreproductible
    .
    

APAR Information

  • APAR number

    HD47888

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2005-12-23

  • Closed date

    2005-12-23

  • Last modified date

    2006-03-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R516 PSN

       UP