Error description
SKETCH TRACER \ IMMERSIVE SKETCH \ CANNOT BE CREATED USING DLNAME DIRECTORIES . SCENARIO: 0) Start CATIA. 1) Turn on DLName Environment. Configure / Add a directory and place any .jpg file in it. 2) Go to V5 / Start / Shape / Sketch Tracer. 3) Select Create an Immersive Sketch icon. 4) Select the .jpg file from the DLName directory. . OBSERVATION: Error occurs, Error initializing Painting 1 The error in the window states, The image file filename.jpg cannot be found. Would you like to manually select this file? . EXPECTED RESULT: DLNames Environment should not cause errors creating an immersive sketch. . ADDITIONAL INFORMATION: If you switch to the Folder Environment, instead of DLName, it works without problem. .
Local fix
Problem summary
SKETCH TRACER \ IMMERSIVE SKETCH \ CANNOT BE CREATED USING DLNA ME DIRECTORIES SKETCH TRACER \ IMMERSIVE SKETCH \ CANNOT BE CREATED USING DLNAME DIRECTORIES . SCENARIO: 0) Start CATIA. 1) Turn on DLName Environment. Configure / Add a directory and place any .jpg file in it. 2) Go to V5 / Start / Shape / Sketch Tracer. 3) Select Create an Immersive Sketch icon. 4) Select the .jpg file from the DLName directory. . OBSERVATION: Error occurs, Error initializing Painting 1 The error in the window states, The image file filename.jpg cannot be found. Would you like to manually select this file? . EXPECTED RESULT: DLNames Environment should not cause errors creating an immersive sketch. . ADDITIONAL INFORMATION: If you switch to the Folder Environment, instead of DLName, it works without problem. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 14. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 17 GA level . Explaination: DLNames Environment do not cause errors when creating an immersive sketch. Immersive sketch is created without any error. .
APAR Information
APAR number
HD47848
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
514
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-12-21
Closed date
2005-12-21
Last modified date
2005-12-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
21 December 2005