APAR status
Closed as user error.
Error description
Selection of MachiningArea Rep is incorrect. . SCENARIO: - Build the provided CAA workspace, - Launch CATIA, - File/Open the provided CATProcess, - Go to Prismatic Machining Workbench, - Select DisplayTreeView button, - Move the mouse over the geometry, ---> Sometimes the geometry is selected (KO), ---> Sometimes the MachiningArea is selected (OK). .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
This is a user error. . Incident Diagnosis: Selection of MachiningArea Rep is incorrect . Correct Application: This error is due to NULMachinableTreeViewCmd being a CATCommand and no selection filter being used. . Currently since the NULMachinableTreeViewCmd is a CATCommand, it creates a new NULMachinableTreeViewPanel and then command 'dies'. Hence the selection then is not in the command context. It is a general rep selection and depending on the view, pick point, the machinable area rep or the underlying part rep is selected. . NULMachinableTreeViewCmd should be a CATStateCommand so that the command is alive even after creating the TreeViewPanel and then a CATPathElementAgent selector can be assigned with ElementType filter as CAAIMachinableArea so that only the machinable area feature can be selected. . Modified files (in attached workspace): WksVisuMachFeat\CAAMachinableFW\CAAMachinabl eUI.m\LocalInterfaces\NULMachinableTreeViewCmd .h WksVisuMachFeat\CAAMachinableFW\CAAMachinabl eUI.m\src\NULMachinableTreeViewCmd.cpp . Documentation Reference: CAA encyclopedia 3D PLM Enterprise Architecture User Interface - Commands Getting Started with State Dialog Commands .
APAR Information
APAR number
HD46951
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
515
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-11-24
Closed date
2005-12-09
Last modified date
2006-01-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
27 January 2006