Error description
GPS : The maximum 'Von Mises Stress' value is not changed even if Young modulus balue has been changed. . SCENARIO: 1) Open the provided CATAnalysis into GSA Workbench RESULT: Value of maximal VM stress is 2.84654E8 N_m2 2) Double-click on the CATPart. Workbench is changed to 'GSD'. 3) Double-click 'Steel'. 4) Select 'Analysis' tab and change the value of 'Young Modulus' into 1N_m2. 5) Click 'OK'. 6) Double-click 'Finite Element Model.1'. 7) MB3 on 'Von Mises Stress.1' and select 'Activate/Deactivate' by context menu. 8) Click 'OK'. 9) MB3 on 'Extrema' and select 'Local Update' by context menu. PROBLEM: The maximum 'Von Mises Stress' value is not changed. .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS PROBLEM IS CONSIDERED AS A USER ERROR. . Incident Diagnosis The maximum Von Mises Stress value is not changed even if Young modulus value has been changed . Correct Application The maximun stress in this case is : sigma = Mf / ( I / v ) where : Mf is the bending moment I the inertia v the maximun distance to the neutral fiber. This is independant of the Young modulus. . Documentation Reference none Getting Started none .
APAR Information
APAR number
HD45593
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
515
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-10-18
Closed date
2005-10-21
Last modified date
2005-10-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
21 October 2005