Error description
HUMBLD : MANKIN NOT PROPERLY LOADED BY "NEW FROM". SCENARIO: 0) Start CATIA V5R15SP3. 1) Open the file : "abc.CATProduct". Workbench : "Human Builder".Note the manikin posture. 2) Close "abc.CATProduct". 3) Select "File" > "New From" in the menu bar."File Selection" panel appears. 4) Select "abc.CATProduct" and click on "Open" button."abc.CATProduct" is created.Notice that the manikin posture is not the one defined in the original "HNJ0144.CATProduct". . Actual RESULT:The manikin modification is not valid when a new file is created by "New From" command. . Expected RESULT:The manikin modification should be effective on the new file created by "New From" command. .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT WHICH CANNOT BE INCORPORATED IN VERSION V5R16 +---------------------------+ | TYPE CLOSING " SUG " | O : OBLIGATOIRE +---------------------------+ F : FACULTATIF Incident Diagnosis This IR reflects a technical limitation of our current (Human Builder) architecture. Explanation follows. When the 'New From' command is executed, the manikin created acts as if it was a new manikin (which is really the case). However, this new manikin is not able to assign the old manikin's data to itself, because the new manikin has a different ID (in fact, each manikin has a unique ID). It therefore behaves as any new manikin would, that is, it goes to the default posture and position. To be able to overcome this limitation, we would have to reconsider our architecture. We are NOT saying that this is not possible; it IS possible, but we cannot do this kind of work at this stage of V5R15 or V5R16. We understand that this issue comes from a customer, but because of the complexity of the change that would be required to make this work, such a technical change will have to be addressed only in a new release. This IR will therefore have to be treated as an enhancement request. We will log the issue in our internal suggestions list. Development Request Justification See above. Answer and By-Pass For the current release, we may recommend that the user (customer) use catalogs as a workaround. That is, the user could save all relevant manikin parameters in a catalog, then, once the 'New From' is done, open the catalog previously saved, and apply the correct data (posture, anthropometry, position, ...) to the new manikin created. .
APAR Information
APAR number
HD43525
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
515
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-08-22
Closed date
2005-08-26
Last modified date
2005-08-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
26 August 2005