Error description
GSD \ SWEEP \ SWEEP GIVES ERROR IF INPUT CONIC CURVE PARAMETER IS REDUCED . 1) 4 conic curves were created in the GSD Workbench and joined together as a line to create a swept surface with 4 locations for the vertices where values could be changed. 2) When the conic values are 0.5 , a sweep can be created. 3) Howvere if the first conic only is lowered to 0.4 this fails with Internal error using geometrical package failed sweep topological error. The other three can be updated fine using 0.4 but not the first conic. .
Local fix
Problem summary
GSD \ SWEEP \ SWEEP GIVES ERROR IF INPUT CONIC CURVE PARAMETER IS REDUCED GSD \ SWEEP \ SWEEP GIVES ERROR IF INPUT CONIC CURVE PARAMETER IS REDUCED . 1) 4 conic curves were created in the GSD Workbench and joined together as a line to create a swept surface with 4 locations for the vertices where values could be changed. 2) When the conic values are 0.5 , a sweep can be created. 3) Howvere if the first conic only is lowered to 0.4 this fails with Internal error using geometrical package failed sweep topological error. The other three can be updated fine using 0.4 but not the first conic. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 16 GA level. . Incident Diagnosis: "internal error" message raised on a specific draft sweep computation with imposed angle values. Very small inconsistency between curve lengths computations leads to too closed imposed sampling parameters and finally to an invalid knot vector in final sweep surface. . Correction Explanation: Now we check imposed sampling parameters equality with appropriate tolerance before elimination. .
Temporary fix
Comments
APAR Information
APAR number
HD42319
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
514
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-07-20
Closed date
2005-08-04
Last modified date
2005-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R516 PSN
UP