APAR status
Closed as program error.
Error description
Send to CATIA V5 as Assembly does not open the primary contend, it opens the folder doc attached to the part . 1) Logon to EV5 2) Create a PRC and open it in Product Editor 3) Under PRC insert an assembly part. Lock usage and reference 4) In Content management, create a folder, a document doc1 and a document doc2 Documents have to be CATPart with simple geometry (pad for instance) 5) Copy doc2 and paste it under folder 6) In Product Editor, select assembly part and go to document tab. 7) From content management select doc1 and copy it 8) Go back to Product Editor and paste special on document in order to paste doc1 as primary document. 9) Copy the folder from content management and paste it in document tab as None 10) Commit 11) Select assembly part from Product Editor and send it to CV5 as assembly Result : document opened is the one inside the folder not the primary. . .
Local fix
Problem summary
Send to CATIA V5 as Assembly does not open the primary c ontend, it opens the folder doc attached to the part Send to CATIA V5 as Assembly does not open the primary contend, it opens the folder doc attached to the part . 1) Logon to EV5 2) Create a PRC and open it in Product Editor 3) Under PRC insert an assembly part. Lock usage and reference 4) In Content management, create a folder, a document doc1 and a document doc2 Documents have to be CATPart with simple geometry (pad for instance) 5) Copy doc2 and paste it under folder 6) In Product Editor, select assembly part and go to document tab. 7) From content management select doc1 and copy it 8) Go back to Product Editor and paste special on document in order to paste doc1 as primary document. 9) Copy the folder from content management and paste it in document tab as None 10) Commit 11) Select assembly part from Product Editor and send it to CV5 as assembly Result : document opened is the one inside the folder not the primary. . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON ENOVIA VERSION 5 RELEASE 16 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R15SP03 ON V5R14SP08. . The primary designation is not enough to let CATIA know that it should be loaded. From the documentation, in the "ENOVIA Life Cycle - Inserting a New Document into the Product Structure" page: . If you intend to create multiple CAD representation documents that are to be attached to a single part reference, you will need to designate one of the documents as the automatic CAD representation selection. The automatic CAD representation selection is the CAD document that automatically opens when you send the part to CATIA. You designate a document as the automatic CAD representation by clicking the Define as Geometry box. . This is the methodology to define which document will be loaded. This was not working and this is what has been fixed in this apar .
Temporary fix
Comments
APAR Information
APAR number
HD40607
Reported component name
ENOVIA LCA AIX
Reported component ID
569101700
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-06-07
Closed date
2005-08-02
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ENOVIA LCA AIX
Fixed component ID
569101700
Applicable component levels
R514 PSN SP51408
UP05/12/16 N 1000
R515 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDJRN","label":"ENOVIA LCA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
24 June 2009