APAR status
Closed as unreproducible in next release.
Error description
Generative Drafting - Hidden lines reappear in SHOW mode after an update of the CATDrawing . SCENARIO: - Open customer's CATPart - File / New from: select customer's CATDrawing - Select "All Views" icon from 'Wizard' Toolbar and Select xy-plane from CATPart from spec. tree and generate the drawing - Select all views from spec. tree - RMB - Properties: Activate "Hidden Lines" from "Properties" - Select all hidden lines from front view - RMB - Hide - Change to 3D - modus and change the diameter of hole.2 (double click) from 10 to 11 mm - Update the 3D-model - Change to 2D modus - Update drawing . RESULT: Some of the lines become visible .
Local fix
Problem summary
Generative Drafting - Hidden lines reappear in SHOW mode after an update of the CATDrawing Generative Drafting - Hidden lines reappear in SHOW mode after an update of the CATDrawing . SCENARIO: - Open customer's CATPart - File / New from: select customer's CATDrawing - Select "All Views" icon from 'Wizard' Toolbar and Select xy-plane from CATPart from spec. tree and generate the drawing - Select all views from spec. tree - RMB - Properties: Activate "Hidden Lines" from "Properties" - Select all hidden lines from front view - RMB - Hide - Change to 3D - modus and change the diameter of hole.2 (double click) from 10 to 11 mm - Update the 3D-model - Change to 2D modus - Update drawing . RESULT: Some of the lines become visible .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5RELEASE 14. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 16 GA level AND ON V5R15SP01 AND ON V5R14SP07 LEVELS All elements in no show stay now in no show after the CATDrawing update .
APAR Information
APAR number
HD39100
Reported component name
CATIA V5 AIX
Reported component ID
569101000
Reported release
514
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-05-03
Closed date
2005-05-13
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 AIX
Fixed component ID
569101000
Applicable component levels
R514 PSN SP51407
UP05/07/05 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: