APAR status
Closed as Permanent restriction.
Error description
ASSEMBLY DESIGN Some files are not loaded while opening a product. Then, once manually loaded, parts are not visible .
Local fix
Problem summary
ASSEMBLY DESIGN Some files are not loaded while opening a produ ct. Then, once manually loaded, parts are not visible ASSEMBLY DESIGN Some files are not loaded while opening a product. Then, once manually loaded, parts are not visible .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . Incident Diagnosis: ASSEMBLY DESIGN Some files are not loaded while opening a product. Then, once manually loaded, parts are not visible . Restriction Explanation: The scenario deals with different problems. The main problem is that data are corrupted. Part files are not the ones expected by the Product. They have the right name, can be located on the file system, but contains internal information that are not compliant with what the product file expected. . It is possible that some files have been directly replaced with others (same name) by the customer into the file system. If so, it is not a good thing, and this manipulation is not supported by CATIA. Files can be replaced with a file with the same name only if this file has been generated by a Save As command of the first one. . In such corruption cases, Replace command has to be used directly. Using File Desk is useless. From CATIA point of view, replacing Parts will be completely different from the ones expected. . However, for complex reasons, the replace command fails partially and the geometry is not displayed at the end of the command. Replace command is not able to clean all problems. After that command, Data not to be cleaned again. Then, when reopened, Geomerty will appear normally. . A last word concerns the "Replace All references" option. When the reference can not be found or corrupted (CATPart file), option is of no use, because we are not able to find all instances of the reference. So, the Replace has to be performed on all the instances, one by one. . By-Pass: Perform replace commands (in desk/links) on all needed Parts. Save everything. Perform cleaner operation on the Product file. Save and reopen the product. .
Temporary fix
Comments
APAR Information
APAR number
HD36437
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
513
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-03-10
Closed date
2005-03-25
Last modified date
2005-03-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"513","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 March 2005