IBM Support

HD18348: GENERATIVE DRAFTING - SYMBOLIC FILLET ARE NOT FULLY CREATED IN AN ISOMETRIC VIEW

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Generative Drafting - Symbolic fillet are not fully
    created in an isometric view
    SCENARIO:
    Create an isometric view with symbolic fillet
    RESULT:
    A part of the Symbolic fillet representation is
    missing
    .
    

Local fix

Problem summary

  • Generative Drafting - Symbolic fillet are not fully created in
    an isometric view
    Generative Drafting - Symbolic fillet are not fully
    created in an isometric view
    SCENARIO:
    Create an isometric view with symbolic fillet
    RESULT:
    A part of the Symbolic fillet representation is
    missing
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 14 GA level.
    Incident Diagnosis
    Symbolic fillets wrongly displayed in drafting
    isometric view
    Correction Explanation
    Symbolic fillets wires are :
    1. shifted in 3D the outside direction of the matter
    in order not to be removed by the HLR : the
    shifting direction was wrong in this case, and too
    important, as seen in the isometric view
    2. once projected, they are relimited in order not to
    touch the projected faces around : the relimitation
    was too important in this case
    Answer and By-Pass
    update the drawing with the fix, the views will look
    better
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD18348

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2004-02-25

  • Closed date

    2004-04-16

  • Last modified date

    2004-04-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R514 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 April 2004