IBM Support

HD13728: DOCUMENTATION : "DISTRIBUTING CATIA V5 ON WINDOWS" DOCUMENTATIO N NEEDS TO BE UPDATED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abstract:
    DOCUMENTATION : "DISTRIBUTING CATIA V5 ON
    WINDOWS" DOCUMENTATION NEEDS TO BE
    UPDATED
    
    Online Documentation reference:
    CATIA Infrastructure Installation Guide /
    Distributing code / Distributing CATIA Version 5 on
    Windows / Accessing the Software from a Thin
    Client / option 11b with UNC paths
    
    Description:
    Customer has written the following information:
    "I did now install V5R11SP03, which shows the
    same problem symptoms: The TOOLS / UTILITY
    window can be started successfully, but it does not
    contain any entries, instead only an empty field is
    displayed. Another company informed me, that
    they have the same problem symptoms. Then I
    tried:
    1. Install V5R11 GA on the server.
    2. Install V5R11 SP03 on the server.
    3. Use the Environment Editor in the server to
    create a global environment with UNC path names.
    4. Connect the server drives to the client via the
    network.
    5. Start CATIA / TOOLS / UTILITY
    = Window appears, but no utility offered in it
    (error).
    Expected result: Utilities (like
    DownwardCompatibility,
    ExtractModelFromSequential, etc.) should be
    displayed.
    6. Install CATIA and SP on the client.
    7. Create a new global environment on the server
    with drive letter path names (C:\Dassault
    Systemes\B11\...), instead of UNC paths.
    8. Start the on the client installed CATIA with the
    new global environment on the server with
    command:
    \\De00ca1\BATB11_SP3
    \intel_a\code\bin\CNEXT.exe -admin -env
    CRH_ADM_R11_SP3 -direnv y:\crhslg\admin\envs
    (Where y: is a from the server mounted network
    drive.)
    9. Start CATIA / TOOLS / UTILITY
    = Window appears and lists all expected utilities
    (=expected result)"
    
    Customer also beleives that, the above written
    scenario will only work (i.e. successfully display the
    different entries in CATIA / TOOLS / UTILITY), if (at
    least) one of the following three points are
    additionally (to the documented steps) ensured:
    
    1) Either both the filename and directory path of
    the server's global Environment file (as created
    during the installation) have to stay identical. (This
    can be achieved by installing CATIA into the same
    UNC path on the server, as the client will later see
    it. In this case no new global Environment file
    needs to be created. Instead the server's
    Environment file can unmodified be used for the
    clients.) (Or it can be achieved, by removing the
    initial global Environment and the creating the new
    desired global Environment with the same name
    and in the same directory.)
    2) Or the files in the installation
    directory ...\intel_a\EnvName.txt
    and ...\intel_a\EnvDir.txt have manually been
    updated, to correctly refer now to the new on the
    server created global Environment filename and
    directory path (as the client sees it).
    3) And/or CATIA is not called
    via ...\intel_a\code\bin\CNEXT -env ... -direnv ...
    (or for admin mode additionally: -admin), but
    instead via ...\intel_a\code\bin\catstart -env ... -
    direnv ... (or for admin mode additionally: -
    run "CNEXT -admin")
    
    None or these three points are described in above
    mentioned documentation reference. Therefore not
    very experienced persons will not perform any of
    them and achieve the problematic result with the
    empty UTILITY panel.
    Hence, The documentation needs to be updated
    with prior consultation with the developers.
    
    .
    

Local fix

Problem summary

  • DOCUMENTATION : "DISTRIBUTING CATIA V5 ON WINDOWS" DOCUMENTATIO
    N NEEDS TO BE UPDATED
    Abstract:
    DOCUMENTATION : "DISTRIBUTING CATIA V5 ON
    WINDOWS" DOCUMENTATION NEEDS TO BE
    UPDATED
    
    Online Documentation reference:
    CATIA Infrastructure Installation Guide /
    Distributing code / Distributing CATIA Version 5 on
    Windows / Accessing the Software from a Thin
    Client / option 11b with UNC paths
    
    Description:
    Customer has written the following information:
    "I did now install V5R11SP03, which shows the
    same problem symptoms: The TOOLS / UTILITY
    window can be started successfully, but it does not
    contain any entries, instead only an empty field is
    displayed. Another company informed me, that
    they have the same problem symptoms. Then I
    tried:
    1. Install V5R11 GA on the server.
    2. Install V5R11 SP03 on the server.
    3. Use the Environment Editor in the server to
    create a global environment with UNC path names.
    4. Connect the server drives to the client via the
    network.
    5. Start CATIA / TOOLS / UTILITY
    = Window appears, but no utility offered in it
    (error).
    Expected result: Utilities (like
    DownwardCompatibility,
    ExtractModelFromSequential, etc.) should be
    displayed.
    6. Install CATIA and SP on the client.
    7. Create a new global environment on the server
    with drive letter path names (C:\Dassault
    Systemes\B11\...), instead of UNC paths.
    8. Start the on the client installed CATIA with the
    new global environment on the server with
    command:
    \\De00ca1\BATB11_SP3
    \intel_a\code\bin\CNEXT.exe -admin -env
    CRH_ADM_R11_SP3 -direnv y:\crhslg\admin\envs
    (Where y: is a from the server mounted network
    drive.)
    9. Start CATIA / TOOLS / UTILITY
    = Window appears and lists all expected utilities
    (=expected result)"
    
    Customer also beleives that, the above written
    scenario will only work (i.e. successfully display the
    different entries in CATIA / TOOLS / UTILITY), if (at
    least) one of the following three points are
    additionally (to the documented steps) ensured:
    
    1) Either both the filename and directory path of
    the server's global Environment file (as created
    during the installation) have to stay identical. (This
    can be achieved by installing CATIA into the same
    UNC path on the server, as the client will later see
    it. In this case no new global Environment file
    needs to be created. Instead the server's
    Environment file can unmodified be used for the
    clients.) (Or it can be achieved, by removing the
    initial global Environment and the creating the new
    desired global Environment with the same name
    and in the same directory.)
    2) Or the files in the installation
    directory ...\intel_a\EnvName.txt
    and ...\intel_a\EnvDir.txt have manually been
    updated, to correctly refer now to the new on the
    server created global Environment filename and
    directory path (as the client sees it).
    3) And/or CATIA is not called
    via ...\intel_a\code\bin\CNEXT -env ... -direnv ...
    (or for admin mode additionally: -admin), but
    instead via ...\intel_a\code\bin\catstart -env ... -
    direnv ... (or for admin mode additionally: -
    run "CNEXT -admin")
    
    None or these three points are described in above
    mentioned documentation reference. Therefore not
    very experienced persons will not perform any of
    them and achieve the problematic result with the
    empty UTILITY panel.
    Hence, The documentation needs to be updated
    with prior consultation with the developers.
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 14 GA level.
    
    Incident Diagnosis:
    Unable to launch CATUtil from the shortcut written
    in documentation.
    
    Correction Explanation:
    CATUtil can not load the correct environement as
    no environment is specified in the shortcut. It is
    now fixed.
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD13728

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-11-10

  • Closed date

    2003-12-18

  • Last modified date

    2003-12-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R513 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 December 2003