Error description
Scenario: ---------- 1. Open any CATPart (the sent CATPart for instance) 2. Save as STEP File 3. Search for UNCERTAINTY_MEASURE_WITH_UNIT (LENGTH_MEASURE(0.005) in the edited step file. == The value of the accuracy is always 0.005mm (in both formats 203 and 214) and not the default accuracy of CATIA 0.001mm. . User has no influence to limit or change this value. It is possible at Import. .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Correct Application : UNCERTAINTY is not a user-defined value and shouldn't be modifi ed by the user. . For the moment, this value is fixed to 0.005mm. . In a future release, this value will be calculated to reflect t he accuracy of the model. This development is nevertheless not scheduled for now. .