IBM Support

HD13032: CANNOT REINSTATE THE LINK BETWEEN DOCUMENT CATDRAWING HAS BROK EN LINK WITH THE PART MESSAGE : THE LINK REFUSED THE DOCUMENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Cannot reinstate link via desk window or with Edit
    / Links. The message The link refused the document
    is given after selection of the part in Edit /
    Links / Replace
    The relationship between a CATpart and its
    CATdrawing is lost.
    Scenario:
    1. Open the CATdrawing
    2. Click on "desk"
    3. Right click on part number highlighted in red
    4. Click on "find"
    5. Choose the correspondent CATpart number and
    than click "open"
    The part number change from red to white it should
    be but the link is not reinstate.
    
    Also, if you make a slight change to the CATPart
    the Update icon lights for the CATDrawing and you
    can pick the icon and no update takes place.
    
    .
    

Local fix

Problem summary

  • Cannot reinstantiate the link between CATDrawing document and
    the part. The message: the link refused the document is given
    Cannot reinstantiate the link via desk window or with Edit
    / Links. The message The link refused the document
    is given after selection of the part in Edit / Links / Replace
    The relationship between a CATpart and its CATdrawing is lost.
    Scenario:
    1. Open the CATdrawing
    2. Click on "desk"
    3. Right click on part number highlighted in red
    4. Click on "find"
    5. Choose the correspondent CATpart number, then click "open"
    The part number change from red to white as it should be
    be but the link is not reinstate.
    Also, if you make a slight change to the CATPart
    the Update icon lights for the CATDrawing and you
    can pick the icon and no update takes place.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Incident Diagnosis
    Cannot reinstantiate link via desk window or with
    Edit / Links. The message:  The link refused the
    document is given after selection of the part in
    Edit / Links / Replace
    Restriction Explanation
    It's impossible to replace a link if the new
    pointed document has not the same uuids as the old
    one.
    Uuid is unique universal identifier.
    In other words, the reroute can be done with files
    that are coming from the Save As only.
    By-Pass
    There is no by-pass.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD13032

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-10-23

  • Closed date

    2004-02-13

  • Last modified date

    2004-02-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 February 2004