IBM Support

HD12410: PART NUMBER IS CHANGE TO UUID AND NEW STATUS IF REPLACE R EVISION ON CATIA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • SMARTEAM CATIA V5 INTEGRATION: Part Number
    is changed to UUID and New status if replace
    revision on CATIA
    .
    Scenario:
    
    1.Prepare the following structure:
    Product1
        + Product2
           + Part1
    2.(User A):Check out Product1 and load it to
    CATIA. Product2 and Part1 are in Copy File mode
    on lifecycle operation.
    3.(User B):Check out Product2 and load it to
    CATIA. Also Part1 is in Check Out mode on
    lifecycle operation.
    4.(User B):Modify Part1 something and then check
    in the whole of Product2.
    5.(User A):Define Part1 as work object and then
    select SmarTeam / Assembly Management/Replace
    with Selected Revision menu.
    6.(User A):Select object with the latest revision.
    Result: Part1 is replaced with the latest revision
    correctly.
    7.(User A):Define Product2 as work object and
    then select SmarTeam / Assembly Management /
    Replace with Selected Revision menu.
    8.(User A):Select object with the latest revision.
    Result: Part Nubmer of the CATPart instance is
    changed to UUID and then status to NEW on the
    specification tree.
    
    .
    

Local fix

Problem summary

  • Part Number is change to UUID and New status if replace       r
    evision on CATIA
    SMARTEAM CATIA V5 INTEGRATION: Part Number
    is changed to UUID and New status if replace
    revision on CATIA
    .
    Scenario:
    
    1.Prepare the following structure:
    Product1
        + Product2
           + Part1
    2.(User A):Check out Product1 and load it to
    CATIA. Product2 and Part1 are in Copy File mode
    on lifecycle operation.
    3.(User B):Check out Product2 and load it to
    CATIA. Also Part1 is in Check Out mode on
    lifecycle operation.
    4.(User B):Modify Part1 something and then check
    in the whole of Product2.
    5.(User A):Define Part1 as work object and then
    select SmarTeam / Assembly Management/Replace
    with Selected Revision menu.
    6.(User A):Select object with the latest revision.
    Result: Part1 is replaced with the latest revision
    correctly.
    7.(User A):Define Product2 as work object and
    then select SmarTeam / Assembly Management /
    Replace with Selected Revision menu.
    8.(User A):Select object with the latest revision.
    Result: Part Nubmer of the CATPart instance is
    changed to UUID and then status to NEW on the
    specification tree.
    
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 11.
    THIS PROBLEM IS NOT REPRODUCIBLE ON
    CATIA VERSION 5 RELEASE 13 GA level AND ON
    V5R12SP03 AND ON V5R11SP07
    COMMENT: Note also that this problem is unreproducible on V5R11
    SP6.
    
    .
    

APAR Information

  • APAR number

    HD12410

  • Reported component name

    SMARTEAM NT 200

  • Reported component ID

    569199970

  • Reported release

    511

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-10-09

  • Closed date

    2003-10-13

  • Last modified date

    2009-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SMARTEAM NT 200

  • Fixed component ID

    569199970

Applicable component levels

  • R511 PSN SP51107

       UP03/12/08 N 1000

  • R512 PSN SP51203

       UP03/11/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: