APAR status
Closed as documentation error.
Error description
Please Investigate this problem. This is Customer original function problem So please apply magic-word before you replay this scenario. This problem occurs by the environment of 'Shape body'. This is the regression problem of CATIA V5R10 When 'Scan' is performed, the feature(Slit', Join', Trim' etc.) does not become Highlight by the geometry area. The parent element of the feature becomes Highlight by the geometry area. Scenario : ------------ 0) Start CATIA V5R11preSP2. Workbench:SHAPDSGN => Please activate the following options ' Tools / Options / Display / Navigation Tab / Selection / Highlight faces and edges ' 1) Open the file : 'xxx3151.CATPart'. 2) Click the 'Scan or Define In Work Object' icon. => 'Scan' window is displayed 3) Move the cursor to 'Split.1' icon on the tree => 'Split.1' is Highlight by the geometry area 4) Move the cursor to 'Split2'icon on the tree. => 'Split.2' is Highlight in the geometry area. 5) Move the cursor to the blue color surface ('Split.1') on the geometry area. => 'Fill.1' is Highlight in the tree. 'Split.1' does not become Highlight 6) Move the cursor to the green color surface ('Split.2') on the geometry area. => 'Offset.1' is Highlight in the tree. 'Split.2' does not become Highlight. => When 'Scan' is performed, the Split feature does not become Highlight in the geometry area. >>> This is problem. . <Result> When 'Scan' is performed, 'Split' does not become Highlight. The parent element (Fill.1 , Offset.1) become Highlight by the geometry area. <Result to expected> When the cursor is moved to the blue surface ('Split.1'), 'Split.1' should be Highlight .
Local fix
Problem summary
GSD : Scan or define in work object : The feature does not bec ome Highlight in the geometry area Please Investigate this problem. This is Customer original function problem So please apply magic-word before you replay this scenario. This problem occurs by the environment of 'Shape body'. This is the regression problem of CATIA V5R10 When 'Scan' is performed, the feature(Slit', Join', Trim' etc.) does not become Highlight by the geometry area. The parent element of the feature becomes Highlight by the geometry area. Scenario : ------------ 0) Start CATIA V5R11preSP2. Workbench:SHAPDSGN => Please activate the following options ' Tools / Options / Display / Navigation Tab / Selection / Highlight faces and edges ' 1) Open the file : 'xxx3151.CATPart'. 2) Click the 'Scan or Define In Work Object' icon. => 'Scan' window is displayed 3) Move the cursor to 'Split.1' icon on the tree => 'Split.1' is Highlight by the geometry area 4) Move the cursor to 'Split2'icon on the tree. => 'Split.2' is Highlight in the geometry area. 5) Move the cursor to the blue color surface ('Split.1') on the geometry area. => 'Fill.1' is Highlight in the tree. 'Split.1' does not become Highlight 6) Move the cursor to the green color surface ('Split.2') on the geometry area. => 'Offset.1' is Highlight in the tree. 'Split.2' does not become Highlight. => When 'Scan' is performed, the Split feature does not become Highlight in the geometry area. >>> This is problem. . <Result> When 'Scan' is performed, 'Split' does not become Highlight. The parent element (Fill.1 , Offset.1) become Highlight by the geometry area. <Result to expected> When the cursor is moved to the blue surface ('Split.1'), 'Split.1' should be Highlight .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN CATIA DOCUMENTATION DELIV ERED WITH CATIA VERSION 5 RELEASE 13. NOTE THAT DOCUMENTATION WILL ALSO BE INCLUDED IN V5R12SP04. Documentation Reference Generative Shape Design Basic Tasks Scanning MODIFICATION: When clicking a sub-element in the 3D geometry, it is in fact the feature used to generate this sub- element which is selected as the in work object. Likewise, this feature is edited when double-clicking a sub-element. .
Temporary fix
Comments
APAR Information
APAR number
HD10657
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
511
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-09-01
Closed date
2003-10-09
Last modified date
2005-10-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
31 October 2005