Error description
Scenario: A simple two part assembly model that successfully solves in GAS in CATI A V5R10 does not solve in V5R11. Material was previously applied to the two parts in V5R10. Steps to recreate problem: 1.) Apply assembly contact constraint between the two parts in Assembly WB. 2.) Start GPS WB and fasten the parts by picking the the assembly contac t constraint in the spec tree. 3.) Clamp one part and apply a load on the other part. 4.) Compute Error message appears in window titled "Error" stating: Wrong number of values Wrong number of characteristic values Characteristic: 1 Mater: 1 Values in call: 1 values stored: 0 Another error message is: Unknown characteristic Characteristic: 1 does not exist for mater: 1 Unable to extract characteristic values .
Local fix
Problem summary
Assembly analysis from CATIA V5R10 does not solve in V5R11 Scenario: A simple two part assembly model that successfully solves in GAS in CATI A V5R10 does not solve in V5R11. Material was previously applied to the two parts in V5R10. Steps to recreate problem: 1.) Apply assembly contact constraint between the two parts in Assembly WB. 2.) Start GPS WB and fasten the parts by picking the the assembly contac t constraint in the spec tree. 3.) Clamp one part and apply a load on the other part. 4.) Compute Error message appears in window titled "Error" stating: Wrong number of values Wrong number of characteristic values Characteristic: 1 Mater: 1 Values in call: 1 values stored: 0 Another error message is: Unknown characteristic Characteristic: 1 does not exist for mater: 1 Unable to extract characteristic values .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev el. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R12SP03 AND V5R11SP07 Incident Diagnosis Assembly analysis from CATIA V5R10 does not solve in V5R11 Correction Explanation Since R11 no ":" or "!" character is allowed in part names. It leads to errors if publications or constraints are used. Now a message appears if you want to use such characters. Answer and By-Pass Rename parts and recreate analysis properties. Then computation is done normally. .
Temporary fix
Comments
APAR Information
APAR number
HD09884
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-08-06
Closed date
2003-11-13
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R511 PSN SP51107
UP03/12/08 N 1000
R512 PSN
UP
R513 PSN
UP