IBM Support

HD08861: CATIA CRASHES AFTER ANALYSIS AND "CLEAR COMPUTATION DATA"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Prob:CATIA crashes after analysis and "Clear
    Computation Data".
    
    Scenario
    1.Open "Fastened_Connection.CATAnalysis;"
    change the workbench to "Generative Structural
    Analysis,"
    if you are not in the workbench.
    2.Click "Compute" icon.
    3.Select "All" in the "Compute" dialog box.
    4.If the check box of "Preview" is checked, remove
    the check.
    5.Click "OK" button; Run the analysis.
    => The window of "Computation Status" is closed
    automatically.
    7. Select "Clear Storage" icon in the "Solver Tools"
    tool bar.
    8.Check "Clear Computation Data;" click "OK"
    button.
    9.Click "OK" button in the "Confirmation" dialog
    box.
    10.Double click "Properties.1" on the specification
    tree to expand it.
    11.Delete "Fastened Connection.1" from the tree.
    12.Operate from Step.2 to Step.5 to analyze again.
    The Computation Status window soon closes
    automatically
    See the "Computation Status" dialog box.
    The message of "Command interrupted" shows up
    in the middle of
    calculation."
    After clicking of "OK" button, the message of "Click
    OK to terminate."
    appears.
    Click "Ok" button in "Runtime exception" dialog
    box.
    Catia crashes.
    .
    1. Load Fastened_Spring_Connection.CATAnalysis.
    Repeat the steps and carry out the analysis as in
    the Fastened
    Connection Case up to step 5.
    6.The Computation Status window will soon close
    automatically.
    Computation complete C 0 No problem
    Repeat the steps and carry out the analysis in the
    same way as for
    Fastened Connection Case steps 7 to 12.
    Also, in Step.11 remove "Fastened Spring
    Connection.1".
    .
    In the provided models
    Fastened_Connection.CATAnalysis and
    Fastened_Spring_Connection.CATAnalysis, only the
    definitions of
    "Properties.1" and Connection in the tree are
    different, the remaining
    settings are absolutely identical.
    .
    cur on the UNIX version.                .
                                            It can be seen from the
    above that,                             If you compare the two c
    ases of "Fastened                       Connection" and "Fastene
    d                                       Spring Connection", even
     though the operation                   carried out is identical
                                            , the former case can be
     analyzed with no problem               whereas in the latter
                                            case CATIA crashes.
    
    Accordingly, there is some kind of problem with
    the "Fastened Spring
    Connection" case.
    .
    After analysis completion, when "Clear
    Computation Data" is selected
    and the defined "Fastened Spring Connection"
    removed, CATIA should not
    terminate abnormally when analysis is then re-
    performed
    
    .
    

Local fix

Problem summary

  • CATIA crashes after analysis and "Clear Computation Data"
    Prob:CATIA crashes after analysis and "Clear
    Computation Data".
    
    Scenario
    1.Open "Fastened_Connection.CATAnalysis;"
    change the workbench to "Generative Structural
    Analysis,"
    if you are not in the workbench.
    2.Click "Compute" icon.
    3.Select "All" in the "Compute" dialog box.
    4.If the check box of "Preview" is checked, remove
    the check.
    5.Click "OK" button; Run the analysis.
    => The window of "Computation Status" is closed
    automatically.
    7. Select "Clear Storage" icon in the "Solver Tools"
    tool bar.
    8.Check "Clear Computation Data;" click "OK"
    button.
    9.Click "OK" button in the "Confirmation" dialog
    box.
    10.Double click "Properties.1" on the specification
    tree to expand it.
    11.Delete "Fastened Connection.1" from the tree.
    12.Operate from Step.2 to Step.5 to analyze again.
    The Computation Status window soon closes
    automatically
    See the "Computation Status" dialog box.
    The message of "Command interrupted" shows up
    in the middle of
    calculation."
    After clicking of "OK" button, the message of "Click
    OK to terminate."
    appears.
    Click "Ok" button in "Runtime exception" dialog
    box.
    Catia crashes.
    .
    1. Load Fastened_Spring_Connection.CATAnalysis.
    Repeat the steps and carry out the analysis as in
    the Fastened
    Connection Case up to step 5.
    6.The Computation Status window will soon close
    automatically.
    Computation complete C 0 No problem
    Repeat the steps and carry out the analysis in the
    same way as for
    Fastened Connection Case steps 7 to 12.
    Also, in Step.11 remove "Fastened Spring
    Connection.1".
    .
    In the provided models
    Fastened_Connection.CATAnalysis and
    Fastened_Spring_Connection.CATAnalysis, only the
    definitions of
    "Properties.1" and Connection in the tree are
    different, the remaining
    settings are absolutely identical.
    .
    This problem does not occur on the UNIX version.
    .
    It can be seen from the above that,
    If you compare the two cases of "Fastened
    Connection" and "Fastened
    Spring Connection", even though the operation
    carried out is identical
    , the former case can be analyzed with no problem
    whereas in the latter
    case CATIA crashes.
    Accordingly, there is some kind of problem with
    the "Fastened Spring
    Connection" case.
    .
    After analysis completion, when "Clear
    Computation Data" is selected
    and the defined "Fastened Spring Connection"
    removed, CATIA should not
    terminate abnormally when analysis is then re-
    performed
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev
    el.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R12SP01 AND
    V5R11SP05.
    Incident Diagnosis
    Despite of being Free/Free modal analysis, result
    displays hi gh frequency
    
    
    Correction Explanation
    problem is fixed. error in code
    
    
    Answer and By-Pass
    none
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD08861

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-07-08

  • Closed date

    2003-08-13

  • Last modified date

    2003-09-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R510 PSN

       UP

  • R511 PSN SP51105

       UP03/09/16 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
23 September 2003