APAR status
Closed as program error.
Error description
Prob:CATIA crashes after analysis and "Clear Computation Data". Scenario 1.Open "Fastened_Connection.CATAnalysis;" change the workbench to "Generative Structural Analysis," if you are not in the workbench. 2.Click "Compute" icon. 3.Select "All" in the "Compute" dialog box. 4.If the check box of "Preview" is checked, remove the check. 5.Click "OK" button; Run the analysis. => The window of "Computation Status" is closed automatically. 7. Select "Clear Storage" icon in the "Solver Tools" tool bar. 8.Check "Clear Computation Data;" click "OK" button. 9.Click "OK" button in the "Confirmation" dialog box. 10.Double click "Properties.1" on the specification tree to expand it. 11.Delete "Fastened Connection.1" from the tree. 12.Operate from Step.2 to Step.5 to analyze again. The Computation Status window soon closes automatically See the "Computation Status" dialog box. The message of "Command interrupted" shows up in the middle of calculation." After clicking of "OK" button, the message of "Click OK to terminate." appears. Click "Ok" button in "Runtime exception" dialog box. Catia crashes. . 1. Load Fastened_Spring_Connection.CATAnalysis. Repeat the steps and carry out the analysis as in the Fastened Connection Case up to step 5. 6.The Computation Status window will soon close automatically. Computation complete C 0 No problem Repeat the steps and carry out the analysis in the same way as for Fastened Connection Case steps 7 to 12. Also, in Step.11 remove "Fastened Spring Connection.1". . In the provided models Fastened_Connection.CATAnalysis and Fastened_Spring_Connection.CATAnalysis, only the definitions of "Properties.1" and Connection in the tree are different, the remaining settings are absolutely identical. . cur on the UNIX version. . It can be seen from the above that, If you compare the two c ases of "Fastened Connection" and "Fastene d Spring Connection", even though the operation carried out is identical , the former case can be analyzed with no problem whereas in the latter case CATIA crashes. Accordingly, there is some kind of problem with the "Fastened Spring Connection" case. . After analysis completion, when "Clear Computation Data" is selected and the defined "Fastened Spring Connection" removed, CATIA should not terminate abnormally when analysis is then re- performed .
Local fix
Problem summary
CATIA crashes after analysis and "Clear Computation Data" Prob:CATIA crashes after analysis and "Clear Computation Data". Scenario 1.Open "Fastened_Connection.CATAnalysis;" change the workbench to "Generative Structural Analysis," if you are not in the workbench. 2.Click "Compute" icon. 3.Select "All" in the "Compute" dialog box. 4.If the check box of "Preview" is checked, remove the check. 5.Click "OK" button; Run the analysis. => The window of "Computation Status" is closed automatically. 7. Select "Clear Storage" icon in the "Solver Tools" tool bar. 8.Check "Clear Computation Data;" click "OK" button. 9.Click "OK" button in the "Confirmation" dialog box. 10.Double click "Properties.1" on the specification tree to expand it. 11.Delete "Fastened Connection.1" from the tree. 12.Operate from Step.2 to Step.5 to analyze again. The Computation Status window soon closes automatically See the "Computation Status" dialog box. The message of "Command interrupted" shows up in the middle of calculation." After clicking of "OK" button, the message of "Click OK to terminate." appears. Click "Ok" button in "Runtime exception" dialog box. Catia crashes. . 1. Load Fastened_Spring_Connection.CATAnalysis. Repeat the steps and carry out the analysis as in the Fastened Connection Case up to step 5. 6.The Computation Status window will soon close automatically. Computation complete C 0 No problem Repeat the steps and carry out the analysis in the same way as for Fastened Connection Case steps 7 to 12. Also, in Step.11 remove "Fastened Spring Connection.1". . In the provided models Fastened_Connection.CATAnalysis and Fastened_Spring_Connection.CATAnalysis, only the definitions of "Properties.1" and Connection in the tree are different, the remaining settings are absolutely identical. . This problem does not occur on the UNIX version. . It can be seen from the above that, If you compare the two cases of "Fastened Connection" and "Fastened Spring Connection", even though the operation carried out is identical , the former case can be analyzed with no problem whereas in the latter case CATIA crashes. Accordingly, there is some kind of problem with the "Fastened Spring Connection" case. . After analysis completion, when "Clear Computation Data" is selected and the defined "Fastened Spring Connection" removed, CATIA should not terminate abnormally when analysis is then re- performed .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev el. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R12SP01 AND V5R11SP05. Incident Diagnosis Despite of being Free/Free modal analysis, result displays hi gh frequency Correction Explanation problem is fixed. error in code Answer and By-Pass none .
Temporary fix
Comments
APAR Information
APAR number
HD08861
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-07-08
Closed date
2003-08-13
Last modified date
2003-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R510 PSN
UP
R511 PSN SP51105
UP03/09/16 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
23 September 2003