APAR status
Closed as program error.
Error description
Activated options: (Tools/Options/Infrastructure/Product Structure/Cache Management tab/Cache Activation/ "Work with the cache system") =>activate (Tools/Options/Infrastructure/Part Infrastructure/General tab/Update /"Manual") =>activate. . . 1. Open specific CATProduct 2. Double Click "Part2.1<CUST3356_part2.CATPart>". -> "Part2.1<CUST3356_part2.CATPart>" Change to "Design mode". 3. Click "Part1.1<CUST3356_Part1.CATPart>" and click MB3. ->Context Menu is displayed 4. Select "Replace Component". 5.Open "CUST3356_Part1_a.CATPart". -> "Impacts ON Replace" panel is displayed. 6. Set a radio button to "YES" and click "OK" button. -> Update Status by Part2 -> Warning is displayed. "Impossible to synchronize : the element, from which the external reference Line.1 is created, is missing". 7. Click "Close" button. 8. Double Click "Part1(Part1.1)". -> "Part1(Part1.1)" Change to "Design mode". -> The link of Publication is broken by the CATPart Replace. . Reason : 1. The geometry of "Part2/External References/ Line.1(..!Part1.1!Line.1)" and the geometry of "Part1/Open body.1/Line.1" should be linked. But, the link of Publication is broken and geometry is different. 2. The link of Publication is OK by tree icon and "Parent Children". Expected result : Publication link should be in the state where it is not updated. .
Local fix
Problem summary
The link of Publication is broken by the CATPart Replace Activated options: (Tools/Options/Infrastructure/Product Structure/Cache Management tab/Cache Activation/ "Work with the cache system") =>activate (Tools/Options/Infrastructure/Part Infrastructure/General tab/Update /"Manual") =>activate. . . 1. Open specific CATProduct 2. Double Click "Part2.1<CUST3356_part2.CATPart>". -> "Part2.1<CUST3356_part2.CATPart>" Change to "Design mode". 3. Click "Part1.1<CUST3356_Part1.CATPart>" and click MB3. ->Context Menu is displayed 4. Select "Replace Component". 5.Open "CUST3356_Part1_a.CATPart". -> "Impacts ON Replace" panel is displayed. 6. Set a radio button to "YES" and click "OK" button. -> Update Status by Part2 -> Warning is displayed. "Impossible to synchronize : the element, from which the external reference Line.1 is created, is missing". 7. Click "Close" button. 8. Double Click "Part1(Part1.1)". -> "Part1(Part1.1)" Change to "Design mode". -> The link of Publication is broken by the CATPart Replace. . Reason : 1. The geometry of "Part2/External References/ Line.1(..!Part1.1!Line.1)" and the geometry of "Part1/Open body.1/Line.1" should be linked. But, the link of Publication is broken and geometry is different. 2. The link of Publication is OK by tree icon and "Parent Children". Expected result : Publication link should be in the state where it is not updated. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev el. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP05 and V5R1 2SP01. With this correction, after replacing component , update is req uested . Then Part1.a will be AUTOMATICALLY switched in design mode in order to synchronize external references. .
Temporary fix
Comments
APAR Information
APAR number
HD08465
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-06-30
Closed date
2003-08-07
Last modified date
2006-12-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
NONE 511
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R510 PSN
UP
R511 PSN SP51105
UP03/09/16 I 1000