Error description
1. Associate in a product 2 product from two different directory, that contain 2 part with same name from repective directory. 2. automatic rename onto the part. 3. Try to expand the specification tree. 4. Catia crash.
Local fix
Problem summary
ASSEMBLY - SAME PART NAME CRASHES CATIA *DS COJ on 21 May =============== Customer : THE BOEIN Numero PMR: 000 411 0 Bonj Voici un nouveau PMR pour Mater AIX.: /s/maint5/db/c000/pmr00007299 Abstr ASSEMBLY - SAME PART NAME CRASHES C Scena 1. Unzip each zip file to two seperate fol 2. Create a new Product in the Assembly Design workb 3. Insert + existing component - from the first fo "FIRST_MODEL_-_CYL_AND_CUBE_DETAIL.CATProd 4. Insert + existing component - from the second fo "SECOND_MODEL-_CYL_AND_CUBOID_DETAIL.CATProd At this point "part number conflicts" window appears. Se Autom rename, select Probl Try to expand spec tree all the way. During this action C will crash and no warm start is available. All unsaved wor l Comportement atte catia doesn't cr Test: sur 510SP3 (niveau du cli Test sur V5 NON REPROD Remar Voir les pieces attachees, contiennent un AbendTr Bon cou Celine CO Bur Tel <table border="0" cellSpacing="0"><tr><td class="tdComment">De scription</td></tr></table> =================================== =============================== | INFORMATIONS FOR NT-INTEL OS ============================================================== ==== *DESCRIPTION 1. Associate in a product 2 product from two different directory, that contain 2 part with same name from repective directory. 2. automatic rename onto the part. 3. Try to expand the specification tree. 4. Catia crash. *FIN DESCRIPTION *BY PASS None *FIN BYPASS ----------- Date Fri May 23 17:49:04 CEST 2003 by AIF - ----------- Date Fri May 23 17:49:29 CEST 2003 by AIF - .
Problem conclusion
Incident Diagnosis : ASSEMBLY - SAME PART NAME CRASHES CATIA . Correction Explanation : Management problem of part with the same name . Answer and By-Pass : Corrected. . THIS PROBLEM WILL BE FIXED ON CATIA VERSION 12 RELEASE GA level . NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP05. .
Temporary fix
Comments
APAR Information
APAR number
HD06959
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-05-21
Closed date
2003-08-04
Last modified date
2003-09-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R510 PSN
UP
R511 PSN SP51105
UP03/09/16 I 1000