Error description
SCENARIO : ------------ 1- open the Part 2- as you can see, the white line is not coincidente to the top of the box 3- load the Part Design workbench 4- select the stiffener icon 5- select the white line ==> Topological operators:Invalid profile body . By-pass : if you relimit the line inside the box, there is no m ore problem. .
Local fix
Problem summary
PARTDESIGN / " TOPOLOGICAL OPERATORS : INVALID PROFILE BODY " O CCURS WHEN CREATING STIFFERNER AFTER SHELL SCENARIO : ------------ 1- open the Part 2- as you can see, the white line is not coincidente to the top of the box 3- load the Part Design workbench 4- select the stiffener icon 5- select the white line ==> Topological operators:Invalid profile body . By-pass : if you relimit the line inside the box, there is no m ore problem. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 12 GA level NOTE THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP02 NOTE THIS PROBLEM WILL ALSO BE FIXED ON V5R10SP07 . Comment: this problem is fixed from V5R10 SP06. . INCIDENT DIAGNOSIS: PARTDESIGN / TOPOLOGICAL OPERATORS : INVALID PROFILE BODY OCCUR S WHEN CREATING STIFFERNER AFTER SHELL . TECHNICAL EXPLANATION FOR THE CORRECTION: Stiffener creation was not possible in case profile was bigger than the part. This case was not supported in the new algorithm . . ANSWER AND POSSIBLE BY PASS: Problem has been fixed. Possible by pass is to modify the profile in order to have a sh orter profile. .
Temporary fix
Comments
APAR Information
APAR number
HD05577
Reported component name
CATIA VERSION 5
Reported component ID
569101000
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-04-03
Closed date
2003-07-09
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA VERSION 5
Fixed component ID
569101000
Applicable component levels
R510 PSN
UP
R511 PSN SP51102
UP03/06/06 N 1000