HD04842: IGES : ABEND WHEN OPENING AN IGES FILE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DESCRIPTION:
    ABEND WHEN OPENING AN IGES FILE
    
    STEP BY STEP SCENARIO:
    1. Open the IGES file provided
    2. CATIA Crashes
    

Local fix

Problem summary

  • CAN NOT OPEN IGES FILE
    <br>*DS ONLY
    LGC on 11 Mar. 2003
    ===================
    
    
    
    Problem with CATIA crashing on opening IGES file.
    Scenario reproduced with CXR11rel 10 march 03
    
    * Material *
    On AIX:
    /s/maint5/db/c000/pmr00045531.422
    On NT:
    \\GOMB1DSY\HOME\mdl\Itf\customer\pmr00045531.422
    at DSP:
    /u/lego/RetoursIncidents/Maintenance/pmr00045531.422
    
    * Description *
    CATIA Crashes on opening this IGES file, it will crash just
    after the 100% of the import.
    
    * Customer Scenario *
    1. Open the IGES file provided
    2. CATIA Crashes
    
    Good luck, Laurent - LGC.
    
    <table border="0" cellSpacing="0"><tr><td  class="tdComment">De
    scription</td></tr></table> ===================================
    ===================================
     |                    INFORMATIONS FOR NT-INTEL OS
            |
     ==============================================================
    ========
    *DESCRIPTION
          010
    DESCRIPTION:
          010
    ABEND WHEN OPENING AN IGES FILE
          010
    
          010
    STEP BY STEP SCENARIO:
          010
    1. Open the IGES file provided
          010
    2. CATIA Crashes
          010
    *FIN DESCRIPTION
          010
    *BY PASS
          010
    None
          010
    *FIN BYPASS
          010
    ----------- Date Wed Mar 12 09:18:55 CET 2003 by JRX -----
    Here is the Call Stack :
    
    MakeClampedData(long 3, long 393587720, double * 0x00000120, lo
    ng 3,
    long 1, long 1, long 96, long 3, double * 0x17761828, double *
    0x1776c380, double 3.1622776601684e-008, long & 2, double * &
    0x1775b3d0, long * & 0x1775ac08, long & 3, CATMathPoint * &
    0x00000000, double * & 0x00000000, double * 0x0012c754) line 50
    1 + 12
    bytes
    MakeNurbsCurveClamped(const long 3, const long 6, double *
    0x1775b398, const long 3, const long 1, const long 2, const lon
    g 96,
    const
    long 3, double * 0x17761828, double * 0x00000003, const double
    3.1622776601684e-008) line 379 + 87 bytes
    MakeNurbsSurfaceClamped(const long 3, const long 6, double *
    0x1775b398, const long 393650032, const long 393659264, double
    *
    0x17763330, const long 1, const long 1, long 393661568, long
    393656944,
    double * 0x17761828, double * 0x1776ba70, const double
    3.1622776601684e-008) line 2898 + 40 bytes
    CATPartImportedBSplineSurface::CreateC2(CATListPtrCATSurface &
    {...}, int & 0, int & 0) line 604 + 85 bytes
    
    
    The CD is after a call to MakeNurbsSurfaceClamped.
    It is not always reproduced on the same face.
    --> I cannot give an extract of the IGS file.
    
    Good Luck...
    
    
    
     -------- DATE : Thu Mar 13 14:54:19 2003 by MEF --
    
     Problem in MakeClampedData. See call back
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 12 GA lev
    el.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R11SP02.
    
    EXPLANATION FOR CORRECTION:
    THERE WAS A PROBLEM IN THE CODE THAT IS NOW CORRECTED.
    
    BYPASS AND ANSWER
    THE FILE IS NOW CORRECTLY IMPORTED
    THERE IS NO BYPASS
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD04842

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-03-11

  • Closed date

    2003-04-24

  • Last modified date

    2009-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R510 PSN

       UP

  • R511 PSN SP51102

       UP03/06/06 N 1000