IBM Support

HD04048: FILE EXTENSIONS CREATED BY OUTPUT NC CODE ARE NOT CORRECT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abstract:
    The NC file extensions created by "generate NC Output in Batch
    Mode"
    are not correct when the chosen extension is not CATNCCode.
    
    Scenario:
    Output a NC file with the Panel "generate NC Output in Batch Mo
    de"
    using:
    - NC data Type = NC Code
    - Split files by operation
    
    The files created are:  MyNCFile_1.CATNCCode,
    MyNCFile_2.CATNCCode ...etc
    => This is correct.
    
    Now change the extension in Tools>options>NC
    Manufacturing>Extension. (eg. MYEXT)
    Output NC file the same way as above, the files created are:
    MyNCFile.MYEXT_1, MyNCFile.MYEXT_2 instead of MyNCFile_1.MYEXT
    => This not correct
    
    .
    

Local fix

Problem summary

  • File extensions created by Output NC code are not correct
    Abstract:
    The NC file extensions created by "generate NC Output in Batch
    Mode"
    are not correct when the chosen extension is not CATNCCode.
    
    Scenario:
    Output a NC file with the Panel "generate NC Output in Batch
    Mode"
    using:
    - NC data Type = NC Code
    - Split files by operation
    
    The files created are:  MyNCFile_1.CATNCCode,
    MyNCFile_2.CATNCCode ...etc
    => This is correct.
    
    Now change the extension in Tools>options>NC
    Manufacturing>Extension. (eg. MYEXT)
    Output NC file the same way as above, the files created are:
    MyNCFile.MYEXT_1, MyNCFile.MYEXT_2 instead of MyNCFile_1.MYEXT
    => This not correct
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 12 GA
    level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R 11SP03 AND
    V5R10SP06
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD04048

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-02-19

  • Closed date

    2003-06-05

  • Last modified date

    2003-06-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R510 PSN

       UP

  • R511 PSN

       UP