VBSCRIPT : USER CAN SELECT ITEMS IN TOOLBARS / PULL-DOWN MENU DURING EXECUTION OF A SCRIPT
Local fix
Problem summary
INCIDENT DIAGNOSIS: In some long macros the user could interacts with the application while the script was replaying. The problem happened after a call to the MsgBox or InputBox functions in the script, which cancelled the action of the hidden window used to prevent user interactions during the script replay.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 11 GA level. Problem corrected, After getting value in inputbox or sending message in msgbox, menus are no more accessible.
Temporary fix
Comments
APAR Information
APAR number
HD03468
Reported component name
CATIA V5/NT/200
Reported component ID