IBM Support

HD03221: DMUFIT : TIMES OF SEQUENCE DEFINITION TOO LONG ON CATIA V5R9SP3 COMPARE TO V5R8SP4

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Load a CATProduct containing 2 tracks
    2. Click on "Edit the sequence" icon.
    V5R9sp3 : 3 s
    V5R8sp4 : 3 s
    3. Select Track.1 (track on GMP node) in the Edit the
    sequence
       panel, click on green arrow (right direction).
    V5R9sp3 : 1 min 07
    V5R8sp4 : 8 s
    4. Select Track.2 ( track on GMP group) in the Edit the
    sequence
       panel, click on green arrow (right direction).
    V5R9sp3 : 2 min 09
    V5R8sp4 : 12 s
    5. Confirm this sequence
    .
    Times are too long on Catia V5R9SP3.
    .
    

Local fix

Problem summary

  • INCIDENT DIAGNOSIS:
       perfo problems
       Adding a Track in an empty sequence takes twice
       more time than in V5R8
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 11 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R10SP05.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R9SP09
    
    Note that this problem is corrected on V5R9 SP08 and V5R10 SP04
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
       The Sequence is loaded three times instead of one
       in the Player, when editing it.
       Which leads to call tedious product move 3 times
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD03221

  • Reported component name

    CATIA V 5 SUN

  • Reported component ID

    569104000

  • Reported release

    509

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-01-23

  • Closed date

    2003-03-27

  • Last modified date

    2009-06-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FILE
    

Fix information

  • Fixed component name

    CATIA V 5 SUN

  • Fixed component ID

    569104000

Applicable component levels

  • R509 PSN

       UP

  • R510 PSN SP51005

       UP03/04/25 N 1000

  • R511 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"509","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
23 June 2009