HD03165: INVALID TABLE FROM CSV FILE CREATED IN A DRAWING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible.

Error description

  • Invalid "Table from CSV" file created in a Drawing
    Scenario:
    1) Start Drafting workbench and create a new empty drawing
    2) Create a New View on the default Sheet
    3) Select the command "Table from CSV"
    4) Select the provided file
    5) Select a point in the view
    Result:
    The table is created but with only one column. The expected
    table should be composed of 7 columns, in this example.
    Note 1: You can choose any .csv file provided in Catia
    Documentation, the result is the same (ex: Screws.csv)
    Note 2: In V5R10-SP1, the created table is also wrong.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    CSV file is not read correctly in CATIA.
    The real scenario of this problem after checking with customer
    is:
    - Machine language is French.
    - CSV file is created using MS Excel with 7 columns.
    - When read in CATIA using Table from CSV command of Drafting,
    there is only one column. Fields are not separated and semi-
    column are visible.
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
        CATIA VERSION 5 RELEASE 9
    .
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
        CATIA VERSION 5 RELEASE 11 GA level AND ON V5R10SP04.
    
     REASON:
    This problem is valid on V5R9 but no more on V5R10 and V5R11.
    Now, on V5R10 and V5R11, if the machine is in french or german,
    the column separator used in CATIA is the semi-column and if
    the language is English the separator will be the comma.
    There should be the same behavior between CATIA and Excel
    regarding column separtors.
    .
     BY-PASS on V5R9:
    On V5R9, the by-pass to the problem is to replace manually the
    semi-column by comma.
    

APAR Information

  • APAR number

    HD03165

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    509

  • Status

    CLOSED UR3

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-01-23

  • Closed date

    2003-01-30

  • Last modified date

    2003-03-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R509 PSN

       UP

  • R510 PSN SP51004

       UP03/03/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"509","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: