APAR status
Closed as program error.
Error description
1. Launch CATProduct. 2. Select Stop on collision in tools/options/dmu fitting/ dmu manipulation. 3. Set "Use Voxelisation for collision detection" option. 4. Set "View collision" feedback then click on OK. 5. Activate DMU Navigator workbench and select "Clash Detection (stop)" icon. 6. Set the compass on the part "xxxx" and move it, in order to put the part on collision with Matrice. => some reds points appear, the part ejecteur does not enter in collision with the part "matrice". 7. Select Tools/options/dmu fitting/dmu manipulation. 8. Deactivate "View collision feedback" then click on OK. 9. Move again the part "xxxx". => The reds points do not appears anymore, but the part "xxxx" does not stop, it has been moved through the part "matrice". We can note a bad behavior of this function since there is no "Stop on collision". .
Local fix
Problem summary
INCIDENT DIAGNOSIS: DMUImmersive Review : STOP ON COLLISION FUNCTION DOES NOT WORK
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 11 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R10SP02. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R9SP06. INCIDENT DIAGNOSIS: a missing argument in the call of a function TECHNICAL EXPLANATION FOR THE CORRECTION: The missing argument makes the function returning a bad result (no clash)
Temporary fix
Comments
APAR Information
APAR number
HD00864
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
509
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-11-18
Closed date
2002-11-28
Last modified date
2009-06-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R509 PSN SP50906
UP02/12/12 N 1000
R510 PSN SP51002
UP03/01/15 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"509","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]