APAR status
Closed as program error.
Error description
WORKSHOP: ELECTRICAL HARNESS ASSEMBLY FUNCTION: SPLIT . SCENARIO: --------- . 1 - READ SPECIFIC ASSEMBLY CONTAINING ELECTRICAL ENTITY 2 - GO IN ELECTRICAL HARNESS ASSEMBLY WORKBENCH 3 - SELECT SPLIT FUNCTION RESULT: CATIA WINDOW FREEZE THEN CRASHES WITH A COREDUMP
Local fix
Problem summary
ELECTRICAL HARNESS ASSEMBLY / SPLIT LEADS TO CATIA CRASH
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 11 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R10SP02 . CLOSURE TYPE: PER ------------- . TECHNICAL EXPLANATION: ---------------------- . THERE WAS A BAD MEMORY MANAGEMENT IN THE CASE OF BNS CREATED WITH SPLINE AS EXTERNAL REFERENCES. SOFTWARE HAS BEEN IMPROVED TO AVOID CORE DUMP. . NOTE: ----- . BNS CAN BE SPLITED IF IT IS DEFINED WITH MORE THAN TWO POINTS IN ORDER TO BE ABLE TO FIND A SPLITING POINT ON THE BNS ROUTE IN THE CASE ABOVE, SINCE THE BNS IS DEFINED THANKS TO A SPLINE THE SELECTION OF THE BNS IS NOT POSSIBLE FOR THE SPLIT OPERATION
Temporary fix
Comments
APAR Information
APAR number
HD00842
Reported component name
CATIA VERSION 5
Reported component ID
569101000
Reported release
508
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-11-18
Closed date
2002-11-29
Last modified date
2009-06-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA VERSION 5
Fixed component ID
569101000
Applicable component levels
R508 PSN
UP
R509 PSN
UP
R510 PSN SP51002
UP03/01/15 N 1000