APAR status
Closed as Permanent restriction.
Error description
To log trace informations, we activated the environment variable: . set CNEXTOUTPUT=C:\temp\trace.log . CATIA V5 and ENOVIA DMU Navigator stores their trace informations into this log file. OK . Problem: While running CATIA V5 we could not show into this file and cannot read the trace informations. On UNIX is this no problem. . Workaround: Stop CATIA V5 and read trace log file. Start CATIA V5 again. . We need this functionality to develop some CAA programs.
Local fix
Problem summary
output trace file cannot be read during a CATIA session on NT. It is possible on UNIX plateform.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . The file named through CNEXTOUTPUT var must be kept opened by CATIA process as long as the process lives. In this case, under windows, another process cannot have read access to same file. . For development purposes, we suggest you to use set CNEXTOUTPUT=CONSOLE before running CATIA. Then a console window is created by CATIA where all the cout , printf,... are displayed. . It is not perfect if you eventually want to keep the traces in a file. In this case, what we do is that we copy/paste console window console into a file, what is acceptable until a few thousands lines. . May we remind you that in a standard windows interactive application, couts and printfs are simply discarded | . An alternative that you may try is the use of OutputDebugString or AfxTrace (not directly TRACE because _DEBUG is not defined under mkmk and you are recommended not to define it). . In this case, the traces are displayed in the debugger output window.
Temporary fix
Comments
APAR Information
APAR number
HC93965
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
508
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-05-21
Closed date
2002-05-24
Last modified date
2002-05-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"508","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: