IBM Support

HC93157: IT IS IMMPOSSIBLE TO CHANGE ACTIVATE FRAME IN GEOMETRY AREA .

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ABSTRACT:
    =========
    IT IS IMMPOSSIBLE TO CHANGE ACTIVATE FRAME IN GEOMETRY AREA
    .
    
    
    SCENARIO:
    =========
    1, File open "Drawing2.CATDrawing"
    2, It is immpossible to change activate frame in geometry
    area.
    
    Remarks:
    ========
    1, We can select activate frame in Tree.
    2, We can change activate frame from right view to front
    view.
    3, I renamed view's name because the name displayed in
    Japanese
    despite of English mode.Before renaming file is
    Drawing1.CATDrawing.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    A view cannot be picked whereas EditProperties says it is pi
    ckable.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    
     TECHNICAL EXPLANATION FOR THE RESTRICTION:
    It appears that the Makeup of the view is in NoPick mode
     This case is impossible interactively since the object
    Makeup cannot be accessed interactively. The only given
    access is given for the view(EDIT / PRopoerties).
    Therefore, the only known way to get a Makeup in NoPick mode
    is to set it to NoPick by the use of CAA code in a special
    command developped by the customer.
    If this is the case, the same code must put back the makeup
    in pickmode before ending.
    If not, this means some interaction at one moment could
    have resulted in this behavior, but we need to know exactly
    which interaction. This is the only way to analyse that kind
     further. The correct behavior can be pulled back by using
    contextual menu on the view in the spec tree and by clicking the
    /right view object/Force Pick mode  command.
    BYPASS:
    In the selection tree, right-click on the view, go to
    Right view object/Force Pick Mode.
     The view will be pickable.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC93157

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    508

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-04-24

  • Closed date

    2002-05-03

  • Last modified date

    2002-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"508","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 May 2002