APAR status
Closed as unreproducible.
Error description
WORKBENCH: PRODUCT STRUCTURE . ABSTRACT: SPLIT DIRECTION IS INVERTED WHEN YOU REPLACE A PART BY ANOTHER. .
Local fix
Problem summary
INCIDENT DIAGNOSIS : Split direction is inverted after a replace component in the Product. TECHNICAL EXPLANATION : Split is a children of an intersection curve. Because this intersection is made between two tangent surfaces, there is an instability.
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 7 . THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 9 GA level AND ON V5R8SP01 ANSWER: The good methodology is to change the design and avoid that kind of configuration (Intersection between two tangent surfaces). The correction cannot be delivered at V5R7 level.
APAR Information
APAR number
HC89264
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED UR3
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-01-11
Closed date
2002-05-02
Last modified date
2003-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT_INT
Fixed component ID
569151000
Applicable component levels
R507 PSN
UP
R508 PSN SP50801
UP02/02/20 N 1000