  • DESCRIPTION :
    The CATPart (imported from CATIA V4) cannot be meshed.
    
    STEP BY STEP SCENARIO:
    - Open "FEM02_culasse_V5R7SP3.CATPart".
    - Start/Analysis & Simulation/Generative Structural Analysis
    - Static Analysis : OK.
    - In Finite Element Model/Nodes and Element
    - Double click : OCTREE 3D.1 : Part1
    - In the panel : OCTREE 3D Mesh.
        Global sag : 2,5 mm,
        Element type : Linear.
    - Local : local size, ADD.
     Local Mesh size :
     Supports : Select the faces to apply the entity :
      4 faces (higher).
     Values : 2,5 mm ou 1 mm ==> OK.
    - Select Compute icon.
    - Mesh only ==> OK.
    ==> ERROR : OCTREE 3D.1 mesh : Part1 can't mesh its
    corresponding part
    or assembly connection check the existence and the validity
    of this associed datum.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    THE PART CANNOT BE MESHED
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    
     TECHNICAL EXPLANATION FOR THE RESTRICTION:
    The V4 volumic part contais 2 faces with geometrical
    problems (auto intersection of edges). The problem can be
    seen when those only two faces are migrated from V4.
    
    Those two connected faces are *FAC5073 and *FAC5038 and
    the problem is not detectable when migrating from V4 to
    V5.
    
     BY-PASS:
    The bypass is to redesign the two faces with CATIA V4 or
    V5 by re computing the intersection of the two support
    surfaces : *SUR4241 and *SUR4223
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC88959

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    507

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-01-02

  • Closed date

    2002-05-06

  • Last modified date

    2002-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 May 2002