APAR status
Closed as program error.
Error description
In Tools / Options / Drafting / Dimension, set 'Dimension following the mouse (ctrl toggle)' to OFF. Some dimensions cannot be created on the ellipse : great diameter, small diameter,....
Local fix
Problem summary
INCIDENT DIAGNOSIS: It is impossible to create distance dimensions between a circle (or an ellipse) and a line that goes through its center.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 9 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R8SP02. TECHNICAL EXPLANATION FOR THE CORRECTION: This particular case had not been correctly handled (mapping of the constraint). ANSWER AND POSSIBLE BY-PASS: This problem has been corrected on V5R8 SP2 and V5R9. The distance dimension of value 14 (at right side) and the distance dimension of value 9.2 at bottom side can be created on V5R8 SP2 and V5 R9. . It is not possible today to create the dimensions of value 28 and 18.4. The corresponding development has to be planned.
Temporary fix
Comments
APAR Information
APAR number
HC87451
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-11-13
Closed date
2002-02-26
Last modified date
2003-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA V5 NT_INT
Fixed component ID
569151000
Applicable component levels
R507 PSN
UP
R508 PSN SP50802
UP02/03/25 N 1000