APAR status
Closed as user error.
Error description
A detail view has been created on a section view. The section view profile direction is inverted so that the geometry of the section view is changed. Problem : the detail view is not updated correspondingly. Scenario: 1. File / Open the CATDrawing file and the CATPart file The detail B is created on the section view A-A 2. On the Front View, double click the section line A-A 3. Click Invert Profile Direction 4. exit Now the Section View A-A has been updated. But the Detail B does not update correspondingly. Detail B keeps the old look.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
INCIDENT DIAGNOSIS: Detail view is not updated correspondingly after Invert Profile CORRECT APPLICATION: The definition of a generated view is not linked with the defining view. The projection plane of a detailed view is not linked with the projection plane of the view where it was defined. In case of projection plane problem, the callout will be put in red.
APAR Information
APAR number
HC86858
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-10-29
Closed date
2001-11-09
Last modified date
2001-11-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
09 November 2001