APAR status
Closed as Permanent restriction.
Error description
Absrtact: PARTDESIGN / "ASRESULT WITH LINK" MENU CAN NOT APPEARS WHEN "PASTE.SPECAL". ** Model Dependent **
Local fix
Problem summary
INCIDENT DIAGNOSIS: PARTDESIGN / AS RESULT WITH LINK MENU CAN NOT APPEARS WHEN PASTE.SPECIAL . TECHNICAL EXPLANATION FOR THE RESTRICTION: Data were corrupted by an unknown reason. BY-PASS: To clean the model just create a PAD at the end of Partbody (after Pad.2) and delete it. COPY/PASTE as result with link will be available. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA INCIDENT DIAGNOSIS: PARTDESIGN / AS RESULT WITH LINK MENU CAN NOT APPEARS WHEN PASTE.SPECIAL . TECHNICAL EXPLANATION FOR THE RESTRICTION: Data were corrupted by an unknown reason. BY-PASS: To clean the model just create a PAD at the end of Partbody (after Pad.2) and delete it. COPY/PASTE as result with link will be available. .
Temporary fix
Comments
APAR Information
APAR number
HC84366
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
506
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-09-04
Closed date
2001-09-19
Last modified date
2001-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
19 September 2001