Error description

  • DESCRIPTION:
    .
    1.  Open CATIA.
    2.  From menu select File + New.
    3.  From pop-up window select Part.
    4.  Accept default part name.
    5.  Create pad solid.
    6.  Add a hole to the pad solid.
    7.  Select the hole.
    8.  Select the Rectangular Pattern icon.
    9.  In the Rectangular Pattern Definition window, select
    Instance(s) & Length from the pull-down menu.
    10. Input 3 for instance.
    11. Input 50 for length.
    12. Select edge of pad for reference direction.
    13. Select OK button.
    14. Select the rectangular pattern in the part tree.
    15. Select the Formula icon from the tool bar.
    16. Create a new parameter of type Length.
    17. Name the new parameter Derf.
    18. Give Derf a value of 60.
    19. Select the Apply button.
    20. Select the rectangular Pattern in the part tree.
    21. Select the Length1 parameter.
    22. Select the Add Formula button.
    23. In the Formula Editor window, select Renamed Parameters from
    the members of Parameters list.
    24. Double click on Derf.
    25. Select Okay button.
    26. Verify that the Length1 parameter has been changed from 50
    to 60 in the Formulas window and is a function of Derf.
    27. Select the Okay button.
    28. Double click on the rectangular pattern in the part tree.
    The Length value is still 50.
    .
    29. Cancel the Rectangular Pattern Definition window.
    30. Select the Formula icon from the tool bar.
    31. Select the rectangular pattern in the part tree.
    32. Select the Length1 parameter.
    .
    It has changed back to 50 and is no longer a function of Derf.
    .
    Expected Behavior:  The Length1 parameter would remain a
    function of Derf.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    Problem when trying to drive length parameter of a pattern by
    a formula.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 8 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R7SP02.
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
    Length parameter of a pattern cannot be driven by the user as it
    is the result of spacing*(instances-1).
    The delivered correction is :
    Do not show anymore length parameters to the user.
    It is no more possible to add a formula to a pattern length
    parameter through formula panel (it was not through pattern
    panel).
    .
    Edition of a pattern will remove it for existing patterns.
    Comments will be added in documentation.
    
     ANSWER AND POSSIBLE BY-PASS:
    Instead of length parameter, use spacing * (instances-1)
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC82995

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    506

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-07-27

  • Closed date

    2001-08-17

  • Last modified date

    2001-09-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R506 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 September 2001