IBM Support

HC64526: USING A 3DLABS OXYGEN GVX1 GRAPHICS CARDS, WHEN YOU MOVE FAST THE SPECIFICATION TREE-->THE GRAPHIC INTERFACE LOCKS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible.

Error description

  • Environment: Catia V5R3 SPX on Windows NT4 SP4
    
    Description: In the Part Design Workbench, when you move fast
    the specification tree, the graphic interface locks. You can't
    move the mouse either. You have to start up again Windows NT.
    GRAPHIC CARD: 3Dlabs Oxygen GVX1, 1280x1024x32bits/pixel, 85Hz,
    32Mb.
    
    Note that same problem occurs when being in the drawing
    workbench, if you move fast a view then graphics interface
    locks as well.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    ------------------------------------------------------------
    This problem is dependent on the graphic driver level used
    on 3DLabs Oxygen GVX1 graphic adapter.
    The problem can be reproduced with driver level 2.14.1053.
    It is corrected in version 2.14.1357 of 3DLabs OXYGEN GVX1
    graphic drivers.
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
        CATIA VERSION 5 RELEASE 3
    .
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
        CATIA VERSION 5 RELEASE 5 GA level AND ON V5R*SP**
    
    ------------------------------------------------------------
    This problem is dependent on the graphic driver level used
    on 3DLabs Oxygen GVX1 graphic adapter.
    
    The problem can be reproduced with driver level 2.14.1053.
    It is corrected in a version 2.14.1357 of 3DLabs OXYGEN GVX1
    graphic drivers.
    

APAR Information

  • APAR number

    HC64526

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    503

  • Status

    CLOSED UR3

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2000-04-19

  • Closed date

    2000-09-06

  • Last modified date

    2000-09-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R003 PSN

       UP

  • R103 PSN

       UP

  • R203 PSN

       UP

  • R303 PSN

       UP

  • R703 PSN

       UP

  • R503 PSN

       UP

  • R004 PSN

       UP

  • R104 PSN

       UP

  • R204 PSN

       UP

  • R304 PSN

       UP

  • R704 PSN

       UP

  • R504 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"503","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information