IBM Support

HC44168: PLOT: INCORRECT PS VALUE ( IN HPGL/2 FILE) : PLOT CUT OFF/ CLIPPED WHEN THE SHEET IS NOT ROTATED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABSTRACT:  PS value is incorrectly in hpgl2 data
    
    Prob: PS value is incorrectly in hpgl2 data.
    Operation:
     1. FK FILE / CREATE / XY /
     2. YES
     3. FK PLOT / QUICK / CREATE /
     4. Select A4
     5. YES
     6. Yes
     7. FK PLOT / QUICK / PLOTTING / PRINT /
     8. EXECUTE
    
     => Plotting works fine, but PS value is incorrectly in hpgl2
        data.
    .
    Remark:
     - This problem does not depend on any models.
     - If use dscan as plotter, this problem can work around.
        ( dscan can ignore ps value in hpgl2 data, and can
          re-caluculate  plotter size by itself.)
     - The customer would like to use hpgl2 data by xerox.
    .
    1. XEROX4036 is A0 PLOTTER with Roll-Feed media.
    2. About PS value.
       Create a window with 841*1189 .
       The value of HPGL2 output was 1189+a * 1189+a .
       (a: CATIA margin)
       The A0 plotter can not print more than 841+MARGIN.
       It seemed that the matter began to occur due to
       1189+a*1189+a.
    3. User didn t use the Rotate option with FK PLOT
    

Local fix

Problem summary

  • The PS order gives a length equal to the width . If the
    sheet size has a width greater than the length and if the sheet
    is not rotated inside the PLOT Function , the output file to
    be printed will be cut off / clipped.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 4 RELEASE 2.1 REFRESH 1 GA level  (FREL421R1)
    
    To get the length and the width corresponding to the sheet
    sizes , you have to use the following keyword  *ROT in
    the plotter configuration file setting to a special value
    How to use it :
    Key in : *ROT 999 .
             When the *ROT keyword is initialize to 999 , the
             hpgl2 driver takes into account the values XMAX
             and YMAX of the *SIZE keyword to manage the auto
             rotate .
             It means that the *SIZE keyword must be initialized
             with the physical values of the media
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC44168

  • Reported component name

    CATIA FOR H.P.

  • Reported component ID

    562620000

  • Reported release

    G20

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    1999-03-04

  • Closed date

    1999-03-22

  • Last modified date

    1999-06-10

  • APAR is sysrouted FROM one or more of the following:

    HC44167

  • APAR is sysrouted TO one or more of the following:

    UB61809

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA FOR H.P.

  • Fixed component ID

    562620000

Applicable component levels

  • RG20 PSY UB61809

       UP99/03/23 I 1000

  • RH20 PSY

       UP

  • R421 PSY UB92111

       UP99/06/02 I 1000