Error description
ABSTRACT: PS value is incorrectly in hpgl2 data Prob: PS value is incorrectly in hpgl2 data. Operation: 1. FK FILE / CREATE / XY / 2. YES 3. FK PLOT / QUICK / CREATE / 4. Select A4 5. YES 6. Yes 7. FK PLOT / QUICK / PLOTTING / PRINT / 8. EXECUTE => Plotting works fine, but PS value is incorrectly in hpgl2 data. . Remark: - This problem does not depend on any models. - If use dscan as plotter, this problem can work around. ( dscan can ignore ps value in hpgl2 data, and can re-caluculate plotter size by itself.) - The customer would like to use hpgl2 data by xerox. . 1. XEROX4036 is A0 PLOTTER with Roll-Feed media. 2. About PS value. Create a window with 841*1189 . The value of HPGL2 output was 1189+a * 1189+a . (a: CATIA margin) The A0 plotter can not print more than 841+MARGIN. It seemed that the matter began to occur due to 1189+a*1189+a. 3. User didn t use the Rotate option with FK PLOT
Local fix
Problem summary
The PS order gives a length equal to the width . If the sheet size has a width greater than the length and if the sheet is not rotated inside the PLOT Function , the output file to be printed will be cut off / clipped.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 4 RELEASE 2.1 REFRESH 1 GA level (FREL421R1) To get the length and the width corresponding to the sheet sizes , you have to use the following keyword *ROT in the plotter configuration file setting to a special value How to use it : Key in : *ROT 999 . When the *ROT keyword is initialize to 999 , the hpgl2 driver takes into account the values XMAX and YMAX of the *SIZE keyword to manage the auto rotate . It means that the *SIZE keyword must be initialized with the physical values of the media
Temporary fix
Comments
APAR Information
APAR number
HC44168
Reported component name
CATIA FOR H.P.
Reported component ID
562620000
Reported release
G20
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
1999-03-04
Closed date
1999-03-22
Last modified date
1999-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UB61809
Modules/Macros
FILE
Fix information
Fixed component name
CATIA FOR H.P.
Fixed component ID
562620000
Applicable component levels
RG20 PSY UB61809
UP99/03/23 I 1000
RH20 PSY
UP
R421 PSY UB92111
UP99/06/02 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G20","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
10 June 1999