IBM Support

HC41889: INTEGRATION OF 2D WIREFRAME SKIN ELEMENTS IN THE SKETCHER: INFINITE LINE CREATE BY GSM PRODUCT ARE IGNORED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Infinite lines created in GSM by intersection of plane/plane
    are not visualized in the Sketcher.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    Procedural lines created by *SKD elements are badly managed by
    Sketcher.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 4 RELEASE 2.0 REFRESH 2 GA level  (FREL420R2)
    
    Procedural lines link to *SKD elements are now taken into
    account by the Sketcher.
    They are displayed in yellow and cannot be modified.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC41889

  • Reported component name

    CATIA FOR SGI

  • Reported component ID

    562630000

  • Reported release

    G20

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    1999-01-19

  • Closed date

    1999-02-02

  • Last modified date

    1999-03-08

  • APAR is sysrouted FROM one or more of the following:

    HC40770

  • APAR is sysrouted TO one or more of the following:

    UB60208 UB60209 UB62222 UB62223 UB62224

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA FOR SGI

  • Fixed component ID

    562630000

Applicable component levels

  • R420 PSN UB92022

       UP99/03/08 I 1000

  • RG20 PSY UB60209

       UP99/02/03 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G20","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
08 March 1999