A fix is available
APAR status
Closed as unreproducible in next release.
Error description
VSE/POWER transmits and receives PNET TCPIP buffers based on timer intervals which limit data transport to approx. 90 KB per second for an active connection.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users of PNET TCPIP * **************************************************************** * PROBLEM DESCRIPTION: PNET TCPIP data transfer is limited to * * approximately 90 KB/S per connection. * **************************************************************** PNET TCPIP data transfer is driven by timer interval with a length of 0.5 seconds, i.e. only 2 buffers will be send per second.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
DY47835
Reported component name
VSE/POWER
Reported component ID
5686VS603
Reported release
62C
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-07-30
Closed date
2020-08-05
Last modified date
2020-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UD54380 UD54381
Modules/Macros
IPW$$MM IPW$$PS IPW$$TD IPW$$TS PNODE
SC34274300 |
Fix information
Fixed component name
VSE/POWER
Fixed component ID
5686VS603
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG32M","label":"APARs - VSE\/ESA environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"62C"}]
Document Information
Modified date:
02 October 2020